Product Standards

Quick Links

Information

Product Standards

Industry specific products include electrical equipment for medical devices, automotive and transportation, and basic consumer products. The EMC Shop will help pinpoint the required test equipment for certifying or evaluating your product in order to obatin certification.

Product Standards There are no products in this category.

Subcategories

  • EN 50121

    EN 50121 describes the Characteristics of Railway Systems that affect the electromagnetic enviroment.

    Get Application Support, Pricing, Lead Time and More: Contact Form


    The EMC Shop stock a wide range of immunity and emissions EMC test equipment for satisfaction of Product Standards - EN 50121. 

     

  • EN 50155

    Railway applications - Electronic equipment used on rolling stock

    This standard applies to all electronic equipment for control, regulation, protection, supply, etc., installed on rail vehicles and associated with: - either the accumulator battery of the vehicle; - or a low voltage power supply source with or without a direct connection to the contact system.

    SurgesElectrostatic Discharge and Transient Burst Susceptibility - related test equipment EN 50155.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EN 50370

    EN 50370, Electromagnetic compatibility (EMC) for the product family machine tools; immunity and emissions. The EMC Shop stocks a variety of multi-function transient generators, coupling/decoupling networks, and more for all your electromagnetic compliance testing needs.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EN 55011

    EN 55011:2009 Indus­trial, sci­en­tific and med­ical equip­ment– Radio- frequency dis­tur­bance char­ac­ter­is­tics Lim­its and meth­ods of mea­sure­ment applies to indus­trial, sci­en­tific and med­ical (ISM) equip­ment. The fre­quency range of ISM equip­ment shall not exceed 400GHz; house­hold equip­ment and sim­i­lar equip­ment designed to gen­er­ate and/ or use locally radio- frequency energy.

     Get Application Support, Pricing, Lead Time and More: Contact Form

    Scope of the Tests:

    Equipment designed to generate RF energy for industrial, scientific and medical (ISM) purposes, including spark erosion.

    Specifications:

    Mains terminal voltage 150 kHz – 30 MHz using CISPR-16 LISN; radiated field 30 – 1000 MHz on test site or in situ (Class A only). Group 2 Class A limits apply down to 150 kHz; A1: 1999 introduces emissions limits between 1 and 18 GHz from Group 2 Class B > 400 MHz

     

  • EN 55024

     

    EMC/EMI Testing Services         Radiated Immunity & Susceptibility        Antenna Testing            Emissions Testing

     

    EN 55024 is equivalent to CISPR 24 and applies to, as the name implies, information technology equipment (ITE). EN 55024 defines the immunity test requirements for information technology equipment in relation to continuous and transient conducted and radiated disturbances. Tests within the standard include Electrostatic Discharges (ESD), Electrical Fast Transients (EFT), Surge, Power Frequency Magnetic Fields, Power interruptions, Radio Frequency Interference (RFI).

     

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EN 55032

    Combining and replacing  EN 55022, EN 55013, and EN 5103-1, EN 55032 is the electromagntic compatibility test standard for multimedia equipment including; ITE - information technology equipment, audio, video, broadcast receiver equipment as well as satellite broadcast, cable transmission and lightgin control equipment. The EMC Shop helps manufacturers setup internal pre-compliance testing capabilities permanently or short term (rentals).

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EN 60065

    EN 60065: Audio, video and similar electronic apparatus - Safety requirements

    Get Application Support, Pricing, Lead Time and More: Contact Form

    EN 60065 applies to electronic apparatus designed to be fed from the mains, from a supply apparatus, from batteries or from remote power feeding and intended for reception, generation, recording or reproduction of audio, video and associated signals. It also applies to apparatus designed to be used exclusively in combination with the above-mentioned apparatus. This standard primarily concerns apparatus intended for household and similar general use but which may also be used in places of public assembly such as schools, theatres, places of worship and the workplace professional apparatus intended for use as described above is also covered unless falling specifically within the scope of other standards.

  • EN 60950

    EN 60950 is the Product Safety testing standard for "Information Technology Equipment" (known as ITE). EN 60950 applies to mains and battery powered information technology equipment, including electrical business machines such as computers and office copiers, along with devices for use with telecommunication networks and cable distribution systems.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • IEC 60601-2-27

    IEC 60601-2-27 applies to electrocardiographic monitoring equipments used in a hospital environment as well as when used outside the hospital environment, such as in ambulances and air transport. The test equipment supplied to meec IEC 60601-2-27 combines the sine wave generator, high voltage source, switches and resitors as outlined in Figures 201.102/3/4.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • IEC 60601-1-2

    Rent or buy test equipment to meet IEC 60601: Medical Electrical Equipment Safety & Performance. Validate, test and debug issues with your product before sending it to a test lab for certification



    Get Application Support, Pricing, Lead Time and More: Contact Form



    Transient generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common EFT/Burst Equipment

    • Electrical Fast Transient Generators: Generators for IEC 61000-4-4, typically in 4kV or 8kV models
    • EFT Coupling Clamp: Required for testing data lined to IEC 61000-4-2.
    • Calibration Adapaters: Used to calibrate or verify EFT generator output.
    • Transducer Plate: Used to calibrate EFT/Burst system at coupling clamp.
    • Test Setup: Test table, coupling clamps, etc.

  • EN/IEC 61326-1

    EN 61326 is the European Union’s EMC standard for certain electrical equipment that is involved in control, laboratory use, measurement and test. EN 61326 determines the requirements for emissions and immunity regarding electromagnetic compatibility (EMC) for electrical equipment that operates from a supply, battery or circuit being measured.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    See our products applicable to the EN 61326 standard:

    • ESD
      • 4 kV contact, 4 kV air to IEC/EN 61000-4-2
    • EFT-burst
      • 1 kV AC & DC power, 0.5 kV I/O signal/ control > 3 m to IEC/EN 61000-4-4
    • Surge
      • 0.5 kV power L-L, 1 kV power & long distance I/O signal/control L-E to IEC/EN 61000-4-5
  • IEC 60255-26

    Measuring relays and protection equipment and the Electromagnetic Compatibility Requirements.

    IEC 60255 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • UL 1449

    UL 1449 requirements cover enclosed and open-type Surge Protective Devices (SPDs) designed for repeated limiting of transient voltage surges as specified in the standard on 50 or 60 Hz power circuits not exceeding 1000 V and for PV applications up to 1500 V dc.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    SPDs are marked with a Voltage Protection Rating (VPR) that is obtained during the Nominal Discharge Current test using a 6 kV, 3 kA Combination Wave Generator.