RF Power Line CDN's

The EMC Shop stocks power line coupling decoupling networks for RF conducted immunity testing. The distubance signals are coupled to each conductor in the supply lines according to EN IEC 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. CDNs are available for power supplies from 1 to 5 conductors.

Get Application Support, Pricing, Lead Time and More: Contact Form

RF Power Line CDN's

  • M1 for one line
  • M2 for two lines
  • M2/3 switchable for two or three lines
  • M3 for three lines
  • M4 for lines and
  • M5 for five lines "-10 types" for frequency range 10 kHz to 80 MHz
  • "-3L and -3LN types" for connections without PE "-750V, -760V
  • -1000V types" for higher EUT voltages

RF Power Line CDN's There are 34 products.

Subcategories

  • 1 Line CDN

    1-line CDN's for 1 PE line power compliance testing in accordance to IEC 61000-4-6 and other standards. The M1 power line CDN is used to couple common mode CW and modulated signals onto single power line systems. The M1 can be ideal for automotive systems using the chassis as the DC return

    The EMC Shop carries an assortment of M-type 1 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 2 Line CDN

    2-line CDN's for L+N, DC +, DC- power compliance testing in accordance to IEC 61000-4-6 and other standards.

    The M2 is commonly used for 2 wire power conductor cables.

    The EMC Shop carries an assortment of M-type 2 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 3 Line CDN

    3-line CDN's for L+N+PE, 2L+PE, or 3L power compliance testing in accordance to IEC 61000-4-6 and other standards.

    M3 is used for two line single phase cables.

    The EMC Shop carries an assortment of M-type 3 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 4 Line CDN

    4-line CDN's for 2L+N+PE, 3L+PE, 3L+N, 3L+N+PE power compliance testing in accordance to IEC 61000-4-6 and other standards.

    The M4 is used on three phase power mains with P.E.

    The EMC Shop carries an assortment of M-type 4 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 5 Line CDN

    5-line CDN's for 3L+N+PE power compliance testing in accordance to IEC 61000-4-6 and other standards.

    M5 is used on three phase systems with neutral and protected earth ground conductors.

    The EMC Shop carries an assortment of M-type 5 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

per page
Showing 1 - 12 of 34 items
    • Inquire for specific models available
    • Coupling / Decoupling of disturbing signal to unscreened supply lines (mains) AC + DC
    • 150 kHz – 80 MHz / 230 MHz
    • CDN Connection Types:
      • M: Unscreened Supply Lines (Mains)
      • AF: Unscreened Non-Balanced Interconnection lines 
      • T & RJ: Unscreened Balanced Interconnection lines
      • CAN-BUS: BUS-Lines
      • S, RJ45S, USB, HDMI, FireWire
    Typically In Stock
    Request Quote/More Info
    • 3-Phase EFT, SURGE and Ringwave
    • 3-Phase AC Dips and Interrupts
    • DC Dips and Interrupts
    • Common Mode Short Testing
    • AC and Impulse Magnetic Fields

    Request Quote/More Info
    • Frequency range 30 to 300 MHz
    • 520 V, 10 Amps, M3 version
    • Conforms with CISPR 16-1-2
    • Enables testing to CISPR 16-2-1 and CISPR 15 CDN method
    • Excellent performance
    • Calibration kit available
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
  • Request Quote/More Info
    • Coupling/Decoupling Network (CDN) CDN M Type
    • Designed for IEC/EN 61000-4-6 Conducted RF Immunity Testing
    • CDN M016 switchable M2 or M3 (2 or 3 power lines)
    • Types with 4 mm banana sockets
    • 150kHz to 230 MHz (300 MHz)
    • Rent the Teseq M016 CDN
    In Stock
    Request Quote/More Info
    • AC (V): 600
    • DC (V): 1000
    • CDN M-Type
    • Coupling / Decoupling of disturbing signal to unscreened supply lines (mains) AC + DC
    • 150 kHz – 80 MHz
    • Suitable for IEC 61000-4-6
    Typically In Stock
    Request Quote/More Info
    • 5 power lines
    • Frequency range: 150 kHz to 230 MHz
    • Designed for IEC/EN 61000-4-6
    • AC Voltage: 300V Line to Ground / 520V Line to Line
    • DC Voltage: 400V Line to Ground / 600V Line to Line
    • Max Current 32 Amps
    • Test Voltage: 3.1 kVDC, 2 seconds
    • 4 mm banana sockets
    Inquire
    Request Quote/More Info
    • 150 MHz - 230 MHz Fequency Range
    • Designed for IEC / EN 61000-4-6
    • Two conductor power cable
    • Individual Calibration Included
    • Three Year Warranty
    Typically In Stock
    Request Quote/More Info
    • 0.15...230 MHz
    • 4 mm Safety Banana Sockets
    • 32 A Max. Current Rating
    • 500 VAC 1000 VDC Input Voltage EUT
    Typically In Stock
    Request Quote/More Info
  • 1 Unit In Stock
    Request Quote/More Info
    • 150 kHz to 230 MHz
    • 4 mm Safety Banana Female
    • 32 A Max. Current Rating
    • 250 VAC 400 VDC Input Voltage EUT
    In Stock
    Request Quote/More Info
    • 150 kHz - 230 MHz
    • 4 mm Safety Banana Sockets
    • 32 A Max. Current Rating
    • 250 VAC 400 VDC Input Voltage EUT
    In Stock
    Request Quote/More Info
Showing 1 - 12 of 34 items