MIL-STD-461 CE102

Using the measurement system hardware including the LISN, cable, limiter, attenuator, and spectrum analyzer to measure the voltage at the LISN measurement port. The measurement system software should apply the appropriate correction and conversion factors to reduce the data. The resulting measurement should be 6 dB below the limit ±3 dB.

CE 102 Purpose

Conducted emissions, power leads

This requirement is applicable from 10 kHz to 10 MHz for all power leads, including returns, which obtain power from other sources not part of the EUT.

This test procedure is used to verify that electromagnetic emissions from the EUT do not exceed the specified requirements for power input leads, including returns.

Test Equipment

The test equipment shall be as follows:

a. Measurement receiver

b. Data recording device

c. Signal generator

d. Attenuator, 20 dB, 50 ohm

e. Oscilloscope

f. LISNs

Get Application Support, Pricing, Lead Time and More: Contact Form

MIL-STD-461 CE102 There are 3 products.

Showing 1 - 3 of 3 items
    • EMI test receiver and signal/spectrum analyzer combined in one box
    • Resolution bandwidths in line with CISPR
    • Weighting detectors: max. peak, min. peak, average, RMS, quasi-peak, average with meter time constant, and RMS in line with current CISPR 16-1-1 version
    • Very fast FFT-based time domain
    • Automatic test routine
    Typically In Stock
    Request Quote/More Info
    • EMI test receiver and signal/spectrum analyzer combined in one box
    • Resolution bandwidths in line with CISPR
    • Weighting detectors: max. peak, min. peak, average, RMS, quasi-peak, average with meter time constant, and RMS in line with current CISPR 16-1-1 version
    • Very fast FFT-based time domain scan as an option
    • Automatic test routines
    Typically In Stock
    Request Quote/More Info
    • Rentals ship immediately
    • Monthly Rate Price
    • Current ISO 17025 Calibration Provided
    • Meets CISPR 16-1-1: 2010 and MIL-STD-461
    • Frequency Range: 20 Hz - 40 GHz
    • Configuration Includes:
      • B10: External Generator Control via GPIB
      • B18: Removable Hard Disk
    In Stock
    Request Quote/More Info