MIL-STD-461 CS115

CS115 Purpose

Conducted Susceptibility, bulk cable injection, impulse excitation

This test procedure is used to verify the ability of the EUT to withstand impulse signals coupled onto EUT associated cabling.

Test Equipment

The test equipment shall be as follows:

a. Pulse generator, 50 ohm, charged line (coaxial)
b. Current injection probe
c. Drive cable, 50 ohm, 2 meters, 0.5 dB or less insertion loss at 500 MHz
d. Current probe
e. Calibration fixture: coaxial transmiss
ion line with 50 ohm characteristic impedance,
coaxial connections on both ends, and space for an injection probe around the center
conductor.
f. Oscilloscope, 50 ohm input impedance
g. Attenuators, 50 ohm
h. Coaxial loads, 50 ohm
i. LISNs

Get Application Support, Pricing, Lead Time and More: Contact Form

MIL-STD-461 CS115 There are 27 products.

per page
Showing 1 - 12 of 27 items
    • Frequency range: 20 Hz to 150 MHz
    • Transfer impedance (ZT): 2 Ohms
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 500 Amps DC-400Hz, 100 Amps Beyond 400 Hz
    • N Type Connector
    In Stock
    Request Quote/More Info
  • Quick view
    $2,775.00 N-Type (f)

    Order and ship today F-65 RF Current Monitoring Probe

    • Frequency Range: 10 kHz - 1 GHz
    • Max RF Current: 40 Amps CW
    • Transfer Impedance: 1.5Ω ± 3 DB
    • Style: Clamp on
    $2,775.00
    In Stock
    Request Quote/More Info
    • Meets specifications of IEC 61000-4-6
    • Handles 50 Watts CW
    • Designed for commercial, medical, military and other RF conducted immunity standards
    • Low insertion loss
    Typically In Stock
    Request Quote/More Info
    • Meets specifications of ISO 11452-4
    • Frequency range from 1 MHz up to 400 MHz
    • Designed for automotive BCI testing
    • Low insertion loss
    $3,450.00
    Typically In Stock
    Request Quote/More Info
    • Analog Channels: 4 + EXT
    • Bandwidth (-3dB) @ 50 Ω: 2GHz *1
    • Rise time@ 50Ω: 230 ps
    • Sample Rates: 5 GSa/s (10 GSa/s ESR) @ each channel
    • 10 Megasample Record Length on All Channels
    • Waveform Capture Rate: Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
    • Connections: USB Host 3.0 x2, USB Host 2.0 x2, USB Device 2.0 (USBTMC) x1, LAN(VXI-11/Telnet/Socket)x1, micro SD card x1, Auxiliary output(Pass/Fail, Trigger Out)x1 and HDMI x1

    In Stock
    Request Quote/More Info
    • Frequency range: 20 Hz to 300 MHz
    • Transfer impedance (ZT): 1 Ohm
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 1.5 Amps (100 Amps Peak)
    • N Type Connector
    In Stock
    Request Quote/More Info
    • Suitable for MIL-STD 461 CE101 and other conducted emissions testing
    • Frequency range: 20 Hz to 30 MHz
    • Transfer impedance (ZT): 1 Ohm
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 100 Amps
    • BNC Type Connector
    In Stock
    Request Quote/More Info
    • Frequency range: 10 kHz to 500 MHz
    • Transfer impedance (ZT): 1.0 to 5.0 Ω above 300 kHz
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 40 AMPS
    • Maximum power current: 200 A DC to 400 Hz
    In Stock
    Request Quote/More Info
    • Frequency range: 20HZ - 20 MHZ
    • Transfer impedance (ZT): 1.5Ω to 3 DB 
    • Continuous signal current (CW): 40 A
    • Connector Types- N type or BNC
    In Stock
    Request Quote/More Info
    • Sample Rates: 5 GSa/s (10 GSa/s ESR) @ each channel
    • 10 Megasample Record Length on All Channels
    • Waveform Capture Rate: Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
    • Connections: USB Host 3.0 x2, USB Host 2.0 x2, USB Device 2.0 (USBTMC) x1, LAN(VXI-11/Telnet/Socket)x1, micro SD card x1, Auxiliary output(Pass/Fail, Trigger Out)x1 and HDMI x1

    In Stock
    Request Quote/More Info
    • Meets specifications of IEC 61000-4-6
    • Frequency range from 10 KHz up to 230 MHz
    • Designed for automotive BCI testing
    • Low insertion loss
    Typically In Stock
    Request Quote/More Info
    • Meets specifications of IEC 61000-4-6
    • Handles 100 Watts CW
    • Designed for commercial, medical, military and other RF conducted immunity standards
    • Low insertion loss
    Typically In Stock
    Request Quote/More Info
Showing 1 - 12 of 27 items