ISO 11452

ISO 11452 consists of the following parts, under the general title Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy:

  • — Part 1: General principles and terminology
  • — Part 2: Absorber-lined shielded enclosure
  • — Part 3: Transverse electromagnetic mode (TEM) cell
  • — Part 4: Harness excitation methods
  • — Part 5: Stripline
  • — Part 7: Direct radio frequency (RF) power injection
  • — Part 8: Immunity to magnetic fields
  • — Part 9: Portable transmitters
  • — Part 10: Immunity to conducted disturbances in the extended audio frequency range
  • — Part 11: Reverberation chamber

ISO 11452 There are 29 products.

Subcategories

  • ISO 11452-2 Shielded Room & Test Apparatus

    Rent, buy or lease ISO 11452-2 Shielded Room & Test Apparatus. The EMC Shop specializes in testing for electrical disturbances from radiated electromagnetic energy in car compents and sub assemblies.

    ISO 11452-2 Test Apparatus and Instrumentation

    ISO 11452-2 Shielded Room

    Diagram Test Setup of ISO 11452-2 Shielded Room with Test Apparatus

  • ISO 11452-4 BCI Test

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-4 BCI Test Equipment.

    ISO 11452-4 defines harness excitation methods (BCI testing) for road vehicles; the component test methods for electrical disturbances from narrowband radiated electromagnetic energy.

    Videos: ISO 11452-4 BCI Test Overview

  • ISO 11452-7 Direct RF Injection

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-7 Direct Radio Frequency (RF) Injection Test Equipment. 

  • ISO 11452-8 Magnetic Immunity

    Rent, buy or lease ISO 11452-8 Magnetic Immunity Test Equipment. The EMC Shop specializes in military and aerospace compliance testing.

  • ISO 11452-10 Immunity to Audio Frequencies

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-10 Immunity Test Equipment to Audio Frequencies. 

    Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 10: Immunity to conducted disturbances in the extended audio frequency range

    ISO 11452-10:2009 specifies a conducted voltage test method and procedure for determining the immunity of electronic components of passenger cars and commercial vehicles, regardless of the propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The method is applied to each individual device under test (DUT) lead and is applicable to all power and output leads, as well as low frequency analogue leads. The method is particularly useful in evaluating DUTs with acoustic or visible display functions.

    The disturbances considered in ISO 11452-10:2009 are limited to continuous narrowband electric voltage waveforms.

  • Stripline Antennas for Radiated Immunity

    Strip Lines are made for the generation of homogeneous electromagnetic fields and specified in ISO 11452-5 and EU guidelines 95/94. The strip lines can be used for testing of electrical/electronic submodules (EUB) and their associated cables.

per page
Showing 1 - 12 of 29 items
    • 10kHz–400MHz
    • 260 Watts CW
    • 3dB
    • Meets ISO 11452-4 and DO-160
    • Harmonics: -20 dBc Maximum
    • Output Impedance: 50
    • AC Supply: 100 to 250 VAC, Single Phase
    In Stock
    Request Quote/More Info
  • Quick view
    $19,500.00 Monthly
    Sale!
    • In stock, calibrated and ready to ship
    • Turnkey CDN, BCI and EM Clamp solutions for IEC 61000-4-6
    • 35 Watt, 150kHz to 230 MHz Integrated class A power amplifier (See Teseq NSG4070-45 for expanded capabilities)
      Multiple EUT monitoring options
    • 5.7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Whisper mode
    $19,500.00
    In Stock
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 45 W, 9 kHz to 1 GHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
    • Bulk Current Injection Test Setup - 10 Vrms IEC
    • Complete, easy to setup test kit for EN/IEC61000-4-6 BCI Testing
    • Pre-programmed test sequences and calibration files
    • Ships immediately
    In Stock
    Request Quote/More Info
    • Bulk Current Injection Test Setup - 400mA Automotive
    • Complete, easy to setup test kit for ISO 11452-4 BCI Testing
    • Pre-programmed test sequences and calibration files
    • Ships immediately
    In Stock
    Request Quote/More Info
    • Achieves:
      • 400mA in Substituion Method
      • 200mA in Closed Loop Method
      • 30 V (40V) with 80 % AM (without 6db)
    • Meets:
      • IEC/EN 61000-4-6
      • IEC 60601-1-2
      • ISO 11452-4
      • Most automotive RF conducted immunity tests
    In Stock
    Request Quote/More Info
    • Meets:
      • ISO 11452-4
      • FMC1278
      • GMW3097
      • Many more...
    • Easy Setup and Teting
    • Lightweight and Portable
    • Achieves:
      • 400mA in Substituion Method
      • 200mA in Closed Loop Method
    In Stock
    Request Quote/More Info
    • Complete kit for ISO 11452-8 EMC Testing
    • Test equipment includes:
      • field generating device (radiating loop or Helmholtz coils)
      • magnetic field intensity monitor
      • low frequency (LF) generator
      • low frequency (LF) amplifier
      • voltmeter
      • current monitor
      • artificial network
    In Stock
    Request Quote/More Info
    • Magnetic field tests and measurement DC to 250 kHz
    • Complies to all relevant EMC, Automotive and Military Standards
    • Magnetic field strength up to 1000 A/m at 1000 Hz
    • Fully automated tests with triaxial Helmholtz coil
    • Wide choice of accessories
    In Stock
    Request Quote/More Info
    • Test Systems In Stock
    • Software with Preprogrammed Standards:
      • IEC/EN 61000-4-3
      • MIL-STD 461 RS103
      • ISO 11452-2
      • Custom Test Sequences
    • RF Field Probes, Antennas & Masts Available
    Typically In Stock
    Request Quote/More Info
    • DESIGNED FOR HIGH POWER PULSE AND CW AUTOMOTIVE TESTING APPLICATIONS
    • INSTANTANEOUS WIDE BANDWIDTH
    • BUILT-IN PROTECTION CIRCUITS
    • HIGH RELIABILITY AND RUGGEDNESS
    • CLASS AB LINEARGAN DESIGN
    In Stock
    Request Quote/More Info
    • Most compact equipment
    • Supports BCI testing as per various standard requirements
    • Basic frequency range 9 kHz up to 400 MHz
    • Extendable frequency range up to 1 GHz
    • Built-in 110 W class A amplifier up to 400 MHz
    • Built-in RF switch to connect external amplifier
    • Built-in directional coupler
    • Built-in 3-channel power meter up to 1 GHz
    Typically In Stock
    Request Quote/More Info
Showing 1 - 12 of 29 items