MIL-STD-461 CS101

 

MIL-STD-461 Testing Services         Radiated Immunity & Susceptibility        Antenna Testing            Emissions Testing

 

Get Application Support, Pricing, Lead Time and More: Contact Form

MIL-STD-461 CS101 Purpose

Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz

This test procedure is used to verify the ability of the EUT to withstand signals coupled onto input power leads. There are two methods provided for making measurements of the applied signal. The first uses an oscilloscope with a power input isolation transformer. The second uses a measurement receiver together with a transducer. The transducer is intended to electrically isolate the receiver from the EUT power and reduce the signal levels to protect the receiver.

MIL-STD-461 CS101 Test Equipment

The test equipment shall be as follows:

a. Signal generator

b. Power amplifier

c. Oscilloscope or measurement receiver

d. Coupling transformer

e. Capacitor, 10 μF

f. Isolation transformer

g. Resistor, 0.5 ohm

h. LISNs

i. Transducer for measurement receiver use

 

MIL-STD-461 CS101 Test Setup

MIL-STD-461 CS101 Test Setup

MIL-STD-461 CS101 There are 12 products.

Showing 1 - 12 of 12 items
    • 4-Quadrant – Source and sink current
    • Up to 25 Amp DUT
    • Perform Dropout, Surge, Ripple Simulations
    • Large Standards Library
    • Automotive, Military, Aerospace and Commercial
    In Stock
    Request Quote/More Info
    • Rentals Ship Same Day
    • Up to 900 watts RMS power output
    • Small signal response up to 400 kHz
    • Up to 16A at 13.5 VDC
    • Stable when driving highly capacitive loads.
    • Four-quadrant operation.
    • Use for Military and Automotive Compliance
    • 120V Input
    In Stock
    Request Quote/More Info
    • 4-Quadrant – Can source and sink current
    • ±80V – DC supply for 12V to 48V systems; meets 80V surge requirements
    • 300 kHz Sine – DC ripple tests for all major standards
    • 3µS Rise Time – Exceeds surge and dropout slew rate requirements
    • 3mΩ DC Source Impedance – Out-performs ISO 7637-2 requirements
    In Stock
    Request Quote/More Info
    • Powered from 120V/230VAC
    • Source and Sink (4 quadrant)
    • Drop outs and surges as fast as 1.2µs
    • Small signal response up to 1 MHz
    • 13.5 VDC at up to 28A
    • Field-selectable ±40V, 75V or 150V potential
    Typically in Stock
    Request Quote/More Info
    • Test equipment bundle with software for easy testing
    • Semi-automatic calibration routine significantly reduces labor-intensive tasks for MIL 461 CS101 Testing
    • Ships Same Day
    Typically In Stock
    Request Quote/More Info
    • Magnetic field tests and measurement DC to 250 kHz
    • Complies to all relevant EMC, Automotive and Military Standards
    • Magnetic field strength up to 1000 A/m at 1000 Hz
    • Fully automated tests with triaxial Helmholtz coil
    • Wide choice of accessories
    In Stock
    Request Quote/More Info
    • EN 55103-1, 2
    • EN/IEC61000-4-8
    • Automotive
    • MIL-STD 
    • Generation and measurement of magnetic fields from DC up to 250 kHz
    • Field strengths up to 1000 A/m 
    • Additional Options (separate)
      • Sensor coils
      • Helmholtz coils
      • Test adapter
    In Stock
    Request Quote/More Info
    • 5 Hz to 1 MHz
    • Multi-Purpose Power Amplifier
    • Typical applications are magnetic immunity testing;
    • According to automotive standards or MIL-461 E or F
    • Frequency range (nominal): 5 Hz - 1 MHz
    • Gain at 8 ohm impedance: 26 dB ±3 dB
    In Stock
    Request Quote/More Info
    • Most compact equipment for ripple noise on ac/dc supplies and magnetic fields
    • Built-in LF signal generator
    • Built-in LF amplifier
    • Built-in LF transformer 2:
    • Built-in frequency-selective voltage and current meter
    • Built-in load resistors
    • Automatic self-calibration
    • Frequency Range: 10 Hz - 250 kHz
    In Stock
    Request Quote/More Info
    • Multi-purpose Power Amplifier
    • Can be used within the Frequency Range from DC to 250 kHz
    • Typical applications are magnetic immunity testing according to automotive standards or MIL-461F
    • Frequency range (nominal): DC - 250 kHz
    • Gain at 8 ohm impedance: 26 dB ±3 dB
    In Stock
    Request Quote/More Info
    • One-box transformer and 0.5 ohm load assembly
    • Frequency response 10 Hz to 250 kHz
    • Secondary saturation 50 A per transformer
    • Audio power 2 x 200 W
    • Freely configurable on primary/secondary; serial, parallel, single
    • Turns ratio 2:1 step down
    • Built-in non-inductive load resistor 0.5 ohm, 250 W
    In Stock
    Request Quote/More Info
    • The EMC Shop supplies equipment solutions for all your MIL-STD-461 CS101 and RS101 testing requirements
    • Equiment configurations include:
      • Signal generator
      • Power amplifier
      • Oscilloscope
      • LISNs
      • Radiating loop
      • Coupling transformer
      • Field monitoring sensor
      • Current probe
    In Stock
    Request Quote/More Info