Cable Input Conducted Emissions

Conducted spurious emissions that appear at the cable input to the device must meet the following criteria. The input shall be an NTSC video carrier modulated with a 10 IRE flat field with color burst at a level of 0 dBmV and with a visual to aural ratio of 10 dB. The aural carrier shall be unmodulated. The peak level of the spurious signals will be measured using a spectrum analyzer connected by a directional coupler to the cable input of the equipment under test. Spurious signal levels must not exceed the limits in the following table:

  • From 54 MHz up to and including 300 MHz–26 dBmV
  • From 300 MHz up to and including 450 MHz– 20 dBmV
  • From 450 MHz up to and including 804 MHz15 dBmV

The average of the measurements on multiple channels from 450 MHz up to and including 804 MHz shall be no greater than -20 dBmV. Measurements shall be made with the receiver tuned to at least four EIA IS–132 channels in each of the above bands. The test channels are to be evenly distributed across each of the bands. Measurements for conducted emissions caused by sources internal to the device are to be made in a shielded RF room. Measurements for conducted emissions caused by external signal sources shall be made in an ambient RF field whose field strength is 100 mV/m.

The EMC Shop specializes in RF testing and compliance equipment solutions. Contact us now to acquire test equipment to measure cable input conducted emissions according to FCC Part 15. 

Cable Input Conducted Emissions There are 3 products.

Showing 1 - 3 of 3 items
    • Rigol DSA710 100kHz to 1GHz Spectrum Analyzer
      • 100kHz to 1GHz Frequency Range
      • Displayed average noise level (DANL) <-155dBm/Hz typ. with preamplifier on
      • Minimum resolution bandwidth (RBW) 100Hz
      • Phase noise <-80dBc/Hz @10kHz offset
      • Level measurement uncertainty <1.5dB
      • 8" (800 x 480) high-definition display
      • Linear and logarithmic frequency axis
    • EMI-DSA800
      • For DSA800 Series Models
      • EMI Filter & Quasi-Peak Detector Kit
      • Option can be added by a software key
    • NFP-3
      • 30MHz to 3GHz Frequency Range
      • One set includes four types of probe, provides optimizing sensitivity and resolution
      • Minimum resolution: 2mm; able to capture near field radiation of single circuit line
      • Applicable for electromagnetic leakage testing inside the cable
    • S1210 EMIs
      • Introduces the workspace concept - Manage multiple measurements easily
      • 'Demo' mode included - Trial the software without an instrument and a licence
    In Stock
    Request Quote/More Info
    • FPC1000 Low-Cost Spectrum Analyzer for Emissions Testing
      • Frequency range: 5 kHz to 1 GHz, Upgradable to 2 GHz or 3 GHz
      • Resolution bandwidth settings down to 1 Hz
      • 10.1" WXGA (1366 x 768 pixel) display
      • Wi-Fi-enabled w/ remote control (included)
      • Easy virtual control w/ iOS/Android/PC
      • Low noise floor / High max. input power
      • Receiver mode for EMI debugging on circuit boards, integrated circuits, cable shielding, etc.
    • HM6050-2 Line Impedance Simulation Network
      • Frequency range from 9 kHz to 30 MHz
      • Built-in transient limiter
      • Artificial hand connector
    • HZ540 Near Field Probes
      • Frequency range from 100 kHz to 1/3 GHz
      • Probes included (1 × Electrical Field Probe, 1 × Magnetic Field Probe, 1 × High Impedance Probe)
    • EMC PreCom
      • EMC Precompliance Software (EMC PreCom) -- EMI module part of the HMExplorer software for conducting precompliance measurements (only with HO720 USB/RS-232 or the optional HO732 Ethernet/USB interface)
    In Stock
    Request Quote/More Info
    • FPC1000 Low-Cost Spectrum Analyzer for Emissions Testing
      • Frequency range: 5 kHz to 1 GHz, Upgradable to 2 GHz or 3 GHz
      • Resolution bandwidth settings down to 1 Hz
      • 10.1" WXGA (1366 x 768 pixel) display
      • Wi-Fi-enabled w/ remote control (included)
      • Easy virtual control w/ iOS/Android/PC
      • Low noise floor / High max. input power
      • Receiver mode for EMI debugging on circuit boards, integrated circuits, cable shielding, etc.
    • Teseq ISN T8 Impedance Stabilization Network (ISN) for Unscreened Balanced Pairs
      • For use with one, two, three, or four unscreened balanced pairs
      • Refers schematic circuit example in CISPR 22/32 Figure D.3/G.3
      • Intended for connection to cable category 3 and 5
      • 1000BaseT and PoE application
      • Changeable pin-arrangements with RJ11 and RJ45
    In Stock
    Request Quote/More Info
Showing 1 - 3 of 3 items