Bulk Current Injection Testing

 

EMC/EMI Testing Services              Bulk Current Injection BCI Probes              RF Conducted Testing Services

 

Bulk current injection testing is an efficient manner to inject disturbances along power and data lines up to 1 GHz. Common bandwidths range from 10kHz to 400 MHz, where the ~80 MHz range and higher acts as a good alternative to radiated immunity testing requiring high power RF amplifiers.



The EMC Shop offers custom solutions tailored to your DUT and test parameters. Software is included and specific test sequences will be generated by The EMC Shop staff prior to shipment. Most bulk current injection test equipment is in stock and calibrated, available to ship whether rented or purchased, saving users months of lead time.



Get Application Support, Pricing, Lead Time and More: CONTACT FORM



Pulse generators are supplied with the ancillary equipment called out in specific test setups. Supplying the test diagram ensures the correct solution is provided. It is also to important to distinguish what tests are required vs what tests would be nice to accomplish but not essential.

Bulk Current Injection Testing Video

Bulk Current Injection Testing There are 17 products.

per page
Showing 1 - 12 of 17 items
    • Standard size: 2.5 by 1 by .9 meters
    • Copper Grounding Straps
    • Ideal for CISPR, MIL, IEC and more
    • 1 mm Copper Top
    • Heavy duty casters
    $7,500.00
    1-2 Weeks
    Request Quote/More Info
  • Quick view
    $19,500.00 Monthly
    Sale!
    • In stock, calibrated and ready to ship
    • Turnkey CDN, BCI and EM Clamp solutions for IEC 61000-4-6
    • 35 Watt, 150kHz to 230 MHz Integrated class A power amplifier (See Teseq NSG4070-45 for expanded capabilities)
      Multiple EUT monitoring options
    • 5.7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Whisper mode
    $19,500.00
    In Stock
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 45 W, 9 kHz to 1 GHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
    • Bulk Current Injection Test Setup - 10 Vrms IEC
    • Complete, easy to setup test kit for EN/IEC61000-4-6 BCI Testing
    • Pre-programmed test sequences and calibration files
    • Ships immediately
    In Stock
    Request Quote/More Info
    • Bulk Current Injection Test Setup - 400mA Automotive
    • Complete, easy to setup test kit for ISO 11452-4 BCI Testing
    • Pre-programmed test sequences and calibration files
    • Ships immediately
    In Stock
    Request Quote/More Info
    • 500 Watts Min 
    • 10 kHz to 250 MHz
    • Gain Adjustment 0 to 20dB
    • VSWR: 4: 1: Max
    In Stock
    Request Quote/More Info
    • Achieves:
      • 400mA in Substituion Method
      • 200mA in Closed Loop Method
      • 30 V (40V) with 80 % AM (without 6db)
    • Meets:
      • IEC/EN 61000-4-6
      • IEC 60601-1-2
      • ISO 11452-4
      • Most automotive RF conducted immunity tests
    In Stock
    Request Quote/More Info
    • Meets:
      • ISO 11452-4
      • FMC1278
      • GMW3097
      • Many more...
    • Easy Setup and Teting
    • Lightweight and Portable
    • Achieves:
      • 400mA in Substituion Method
      • 200mA in Closed Loop Method
    In Stock
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Meet IEC 61000-4-6 or MIL-STD-461 CS114
    • Easy to setup and use of software
    In Stock
    Request Quote/More Info
    • 10 kHz - 250 MHz Frequency Range
    • 75 Watt Integrated Amplifier
    • Achieve 40 Vrms with a BCI probe
    • Computer Based System (USB controlled)
    • Self Calibration with Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Typically In Stock
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Typically In Stock
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Easily sweep from 150 kHz to 230 MHz up to 10 Vrms
    • Meet IEC 61000-4-6 with easy plug and play system
    • Easy to setup and use with dedicated laptop/software
    Typically In Stock
    Request Quote/More Info
Showing 1 - 12 of 17 items