Quick Links

Information

EN/IEC 61000-3-2

Meet harmonics and flicker test standards IEC 61000-3-3 using the same power source. "Electromagnetic compatibility (EMC) - Part 3-2 Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)"

Harmonics & Flicker Classification:

Equipment can be grouped into one of 4 classes based on the following criteria as evaluated by the IEC committee members:

  • Number of pieces of equipment in use (how many (volume) are being used by consumers)
  • Duration of use (number of hours in operation)
  • Simultaneity of use (are the same type of equipment used on the same time frame)
  • Power consumption
  • Harmonics spectrum, including phase (how clean or distorted is the current drawn by the equipment)

After all the above criteria are taken into consideration equipment are classified as follows:

  • Class A
    • Balanced three-phase equipment
    • Household appliances, excluding equipment identified by Class D
    • Tools excluding portable tools
    • Dimmers for incandescent lamps
    • Audio equipment
    • Everything else that is not classified as B, C or D
  • Class B
    • Portable tools
    • Arc welding equipment which is not professional equipment
  • Class C
    • Lighting equipment
  • Class D
    • Personal computers and personal computer monitors
    • Television receivers

Get EMC Compliance Standards Support, Pricing, Lead Time and More: Contact Form

EN/IEC 61000-3-2 There are 24 products.

per page
Showing 1 - 12 of 24 items
    • Extremely low harmonic distortion - even under very non-linear load conditions
    • Very fast slew rate > 52V/μs (rise time < 5μs at 230Vrms as required by IEC/EN 61000-4-11)
    • Operates from DC up to 5kHz large signal bandwidth (-3dB) - optional up to 30kHz
    • Small signal bandwidth up to 50kHz or 100kHz
    • High long-term overload characteristic (up to 1-hour)
    • High short-term overload characteristic (for 5 … 10mins.)
    • Very high peak-load ability (up to 5ms)
    • Very low internal resistance
    In Stock
    Request Quote/More Info
    • Full compliance with IEC61000-3-2 standard when used with LDPS power source
    • Fully compliant IEC61000-3-3 flicker measurement
    • Harmonic measurement in accordance with EN61000-4-7 and Flicker as defined by EN61000-4-15
    • P.C. Software and USB interface included for downloading results, archiving and printout
    • Provides an EN61000–3–2 compliant source
    • 1000W power capability at 230V
    • Up to 4·4A rms load current and up to 10A peak currents
    • Comprehensive overload protection
    • Connection via standard power connector
    In Stock
    Request Quote/More Info
    • Full compliance with IEC61000-3-2 standard when used with LDPS power source
    • Fully compliant IEC61000-3-3 flicker measurement
    • Harmonic measurement in accordance with EN61000-4-7 and Flicker as defined by EN61000-4-15
    • P.C. Software and USB interface included for downloading results, archiving and printout
    In Stock
    Request Quote/More Info
    • 40 - 5,000 Hz Output Frequencies
    • Combination AC and DC Power Source and Power Analyzer 
    • Built in Function Generator
    • Scope Capture Capability 
    • EN61000-3-2 and EN61000-3-3
    • Powerful Programming Software 
    In Stock
    Request Quote/More Info
    • 1000 W DC Output
    • 1500 VAC of Output Power
    • Combination AC and DC Power Source and Power Analyzer 
    • AC, DC or AC+DC 
    • Built-in Digital Power Analyzer 
    • Scope Capture Capability 
    • EN61000-3-2 and EN61000-3-3
    • Powerful Programming Software 
    • Constant Power Mode
    In Stock
    Request Quote/More Info
    • 3500 W DC Output
    • 5000 VA of Output Power
    • Combination AC and DC Power Source and Power Analyzer 
    • AC, DC or AC+DC 
    • Built-in Digital Power Analyzer 
    • Scope Capture Capability 
    • EN61000-3-2 and EN61000-3-3
    • Powerful Programming Software 
    • Constant Power Mode
    In Stock
    Request Quote/More Info
    • Output Power: 30,000 VA
    • Output Current, 50 Hz (60 Hz)
      • Inductive Load: 41A (43A)
      • Resistive Load: 34A (33A)
      • Capacitive Load: 27A (26A)
      • ma. 78A (79A) RMS for 3 sec.
      • Repetitive Peak: 300 Amps
    • Input Current: Max 100 Amps
    • Weight: 550 kg
    • Dims (mm): 1670 x 920 x 625
    In Stock
    Request Quote/More Info
  • Request Quote/More Info
    • Real-time data acquisition
    • Meets IEC 61000-3-11, IEC 61000-3-12, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-7, IEC 60601-1-2 and more
    • Wide-range current input: 140 Amps with Standard CT's
    • Wide-range voltage input: 10 - 530V rms
    • Flicker Accuracy: 0.15%
    • USB interface for control and data transfer
    Typically In Stock
    Request Quote/More Info
  • Typically In Stock
    Request Quote/More Info
    • Fully meets the requirements for compliance testing of harmonics
    • Innovative, low cost technique
    • Will provide up to 1kW (4.4A rms) at 230V 
    • 10Amp peak capacity
    • US or Schucko Connector Available
    In Stock
    Request Quote/More Info
    • 3 kVA
    • IEC 61000-3-2 and IEC 61000-3-3 Testing
    • supporting testing on products consuming up to 11 Amps rms and 92 Amp peak @230 Vac
    • single Phase
    • stable, accurate, programmable 3 kVA power source
    • NSG 1007-3 Power source 
    • CCN 1000-1 single phase
    • Coupling unit
    Typically In Stock
    Request Quote/More Info
Showing 1 - 12 of 24 items