AH Systems RF Current Injection Probes

AH Systems Current Probes are devices used in a wide variety of industrial and scientific applications, and designed to be used in the process of generating and measuring high levels of RF current. Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. These EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50 ohm impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables.

AH Systems RF Current Injection Probes There are 7 products.

Showing 1 - 7 of 7 items
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis
    • Broad High Frequency Response: 300 kHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe
    Typically In Stock
    Request Quote/More Info
    • Broadband (instantaneous single band) : 10 kHz – 400 MHz
    • Frequency extension adapter for testing between 4kHz to 10kHz possible with limited power specifications
    • Typical power: 500 W CW
    • Input Power (with respect of core temperature = 80°C) : 150 W - 60 min / 300 W - 30 min / 500 W - 15 min
    • EMC standars covered:
      • DO 160 D
      • Mil STD 461
      • Automotive standards: PSA, Renault, Ford, Daimler Chrysler...
      • ISO 11452-4
      • SAE J1113-4
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 10 kHz - 100 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 13 to 33 dB
    • Max Input Power: 100 Watts CS
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 5 MHz - 1 GHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 5 to 30 dB
    • Max Input Power: 50 Watts
    • Mas Current: 30 Amps
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 1 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 1 MHz - 400 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 22 dB
    • Max Input Power: 100 Watts CS
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Typically In Stock
    Request Quote/More Info
Showing 1 - 7 of 7 items