EM Coupling Clamps

The integrity of both communication and electrical lines within products of all shapes and sizes is important to address early in design stages. EM coupling clamps are used to monitor electrical and magnetic characteristics radiated from electrical/communication wires. Additional, you can generate electrical and magnetic fields using a clamp to inject distrubances onto the lines and evaluate their response. EM clamps are used to meet CISPR, IEC and other compliance standards to evaluate radio frequency disturbances on and around power or data lines.

Get Application Support, Pricing, Lead Time and More: Contact Form

EM Clamp Test Setup per IEC 61000-4-6

EM Coupling Injection Clamp Test Setup per IEC 61000-4-6

EM Injection Clamp Video Overview

EM Coupling Clamps There are 18 products.

per page
Showing 13 - 18 of 18 items
  • Request Quote/More Info
    • Inject noise without cutting the signal line, DC line, AC line and ground line of the equipment under test.
    • Inspection of the level of noise immunity of the electronic equipment for each block or unit.
    • Direct noise injection into the signal line enabling effective checking of the level of noise immunity.
    • 26 mm Diameter for Signal Line Bundle

    Included

    • CA-805B main unit (1 pc).
    • Coaxial cable for input/output 1.5m/ Model: 02-00025A (2 pcs.)
    • Instruction manual (1 pc.) 

    Purchase Noiseken CA-805B

    $295.00
    In Stock
    Request Quote/More Info
    • Correspond to CISPR 16-1-3
    • Measurement of interference power according to CISPR 16-2-2
    • Can be used as a diagnostic tool
    • Measuring the shielding efficiency of coaxial cables
    In Stock
    Request Quote/More Info
  • Quick view
    $249.00 Monthly
    • Construction as per IEC 61000-4-4
    • See our EFT Generators Page
    • EFT/Burst testing of signal and datalines 
    • Pulse voltage up to 5.5kv
    • Cable diameter up to 40mm
    • Effective coupling length 1m
    $249.00
    In Stock
    Request Quote/More Info
    • Frequency range 1 MHz to 1 GHz
    • Frequency range 30 MHz to 200 MHz (CISPR 16-1-4)
    • Max. cable diameter 20 mm
    • Conform with CISPR 16-1-4, CISPR 16-2-3, CISPR 11
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • As specified in CISPR 16-1-3/EN 55016-1-3
    • Disturbance power measuring, according to CISPR 16-2-2/EN 55016-2-2, CISPR 13/EN 55013, CISPR 14-1/EN 55014-1 and EN 50083-2
    • Excellent for using as diagnostic tool and for measurements of screening attenuation of coaxial cables
    • Supplied with 6 dB attenuator and RF cable
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info