Categories

Quick Links

Information

Top sellers

per page
Showing 13 - 24 of 586 items
    • Max EUT Size: (200 x 200 x 150mm) (7.87 x 7.87 x 5.90in.)
    • IEC/EN 61000-4-20 (CEI 210-78)
    • both radiated emission and immunity measurements
    • Testing in Transverse Electromagnetic (TEM) Waveguides
    • (Equipment Under Test) up to a frequency range of 20 GHz
    • Ruggedized fully Hot galvanized and INOX steel construction 
    • Unique compact design. 
    • Optimized for EMI and EMC. 
    • Strong fields achieved with low input power 
    • Broadband up to 20Ghz 
    • High effective shielding
    • 6A 2 poles standard line filter
    • 10A 80V DC 2 poles line filter
    • Excellent quality at Low cost
    In Stock
    Request Quote/More Info
  • Order and ship today DPL200M Pulse Transient Limiter with Fuse Lamp

    • DC - 200 MHz
    • Ideal for Conducted Emissions Testing
    • Built-in 20 dB high power attenuator
    • N Type Connector
    • Alarm for High Energy Detection
    $895.00
    In Stock
    Request Quote/More Info
    • 10 kHz to 1 GHz Frequency Range
    • 40 dB ±1 dB Coupling
    • 100 Watt CW Maximum Input Power
    • Flatness: ±1 dB Max.
    • VSWR: 1.30:1 Max.
    • Directivity: 20 dB Typical
    • Standard N-Type Connection (SMA and others upon request)
    • Package with an RF Power Amplifier
    • Suitable for IEC 61000-4-3, IEC 60601-1-2
    $1,975.00
    In Stock
    Request Quote/More Info
    • 100 Watts Rated power
    • DC to 300 MHz
    • Low return loss (VSWR)
    • Precise attenuation tolerances
    • 6 dB to 50 Ω attenuators
    • particularly for minimizing reflection losses in tests per IEC/EN 61000-4-6
    • also useful for general purposes
    • BNC or N-Type Connectors
    $950.00
    In Stock
    Request Quote/More Info
    • Typical Performance at:
      • 30 MHz = -18.0 dB
      • 100 MHz = -27.0dB
      • 300 MHz = -25.0 dB
      • 500 MHz = -19.5 dB
      • 1000 MHz = -12.5 dB
    • Initial permeability: 2000±20%
    • Relative Loss: 25 (0.1MHz) tanδ/μiac
    • Saturation Flux Density: 260 (1194A/m)
    • 3.93" by 3.93"  (.0265" thick)
    • Minimum Order Requirements Apply
    In Stock
    Request Quote/More Info
    • Measurement Range: 18 - 1090 V/m
    • Dynmaic Range: 37 dB
    • Flatness: ±1.25 dB
    • Isotropic Response: ±1 dB
    • Ideal for Satellite Communication, Leak Detection and Exposure Levels (Partially suitable for Radar Signals)
    In Stock
    Request Quote/More Info
    • Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)
    • High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers
    • Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies
    • Special option available to 18 GHz
    • Precision type-N connector as standard
    • Operates with the EPM-P (E4416A/ 17A) series and P-Series (N1911A/ 12A) power meters
    In Stock
    Request Quote/More Info
    • 500kHz-18GHz CW Power Sensor
    • Fast measurement speed
    • Wide dynamic range (-70 dBm to +20 dBm)
    • Refurbished unit includes:
      • Power Sensor Cable
      • Calibration Certificate
      • User Manual
      • 100 Day Warranty
      • 10% off Calibration Service for Life
    • Excellent SWR for reducing mismatch uncertainty
    • Compatible with the most of Boonton RF power meter series
    $975.00
    Typically In Stock
    Request Quote/More Info
    • High measurement speed and time-saving routines improve throughput
    • Remote control via LAN or IEC/IEEE bus in line with SCPI
    • Excellent price/performance ratio
    • General-purpose signal analysis
    • Wide range of personalities for various wireless/cellular digital standards
    In Stock
    Request Quote/More Info
    • 9 kHz - 3 GHz
    • Automatic EMI measurements
    • High accuracy and response
    • Compatible with the BenchLink Web Remote software
    • Log sweep
    • 5 minute warm-up
    • Built-in preamplifier
    Typically In Stock
    Request Quote/More Info
    • 100kHz to 1GHz Frequency Range
    • Displayed average noise level (DANL) <-155dBm/Hz typ. with preamplifier on
    • Minimum resolution bandwidth (RBW) 100Hz
    • Phase noise <-80dBc/Hz @10kHz offset
    • Level measurement uncertainty <1.5dB
    • 8" (800 x 480) high-definition display
    • Linear and logarithmic frequency axis
    • Connectivity: LAN(LXI), USB Host & Device
    • PictBridge support
    • Compact size and light weight
    • Supplied with... USB cable, UK & European mains leads, quick guide,
    • Optional PC software... Ultra Spectrum, S1210 EMI Pre-Compliance Test
    • Other options include... EMI filter & quasi-peak detector, advanced measurement functions, 2FSK measurement & analysis in signal seamless capture mode, USB to GPIB module, rack mount kit, soft carry bag, RF transmitter demo kit, RF receiver demo kit, high power attenuator, RCL standard calibration

    To Purchase Rigol DSA710

    In Stock
    Request Quote/More Info
    • 100kHz to 1GHz Frequency Range
    • Displayed average noise level (DANL) <-155dBm/Hz typ. with preamplifier on
    • Minimum resolution bandwidth (RBW) 100Hz
    • Phase noise <-80dBc/Hz @10kHz offset
    • Level measurement uncertainty <1.5dB
    • 8" (800 x 480) high-definition display
    • Linear and logarithmic frequency axis
    • Connectivity: LAN(LXI), USB Host & Device
    • PictBridge support
    • Compact size and light weight
    • Supplied with... USB cable, UK & European mains leads, quick guide,
    • Optional PC software... Ultra Spectrum, S1210 EMI Pre-Compliance Test
    • Other options include... EMI filter & quasi-peak detector, advanced measurement functions, 2FSK measurement & analysis in signal seamless capture mode, USB to GPIB module, rack mount kit, soft carry bag, RF transmitter demo kit, RF receiver demo kit, high power attenuator, RCL standard calibration

    To Rent Rigol DSA710

    In Stock
    Request Quote/More Info
Showing 13 - 24 of 586 items