Standards MetIEC 61000-4-5
Mains & EUT Connections4mm banana plug
Pulse voltage (open circuit) 15kV/7500A
Impedance2 Ohm
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
ParameterValue
Pulse current (short circuit) 15kV/7500A
CouplingAC/DC lines CDN, and Telecom lines CDN
Pulse repetition20 sec
PolarityPositive, Negative, Alternate
Phase synchronization0°-360°, 1°step or random
Dimensions555 X 1250 X 790 mm
Weight200 kg.

Test Equipment Description

Fully compliant with the requirements called for in the 2nd edition of IEC 61000-4-5 standard, the LSS-15AX series simulators provide a testing facility for up to 15kV test voltage without sacrificing safety and ease of use. The LSS-15AX simulators generate the two combination pulses 1.2/50 µs (8/20 µs) and 10/700 µs (5/320 µs).

The LSS-15AX series have been newly designed to completely satisfy and exceed the requirements in IEC 61000-4-5 standard. The simulators consist of a combination wave generator applying a 1.2/50 open-circuit voltage wave in a high impedance test piece and delivering an 8/20 short-circuit current wave in a low impedance test piece, CCITT telecom wave generator and associated coupling and decoupling circuits. (the contents depend on the model) With 15kV output capability, the simulators can also be use for evaluating the equipment under test in destructive mode testing.

FUNCTIONS

  • Easy operation
  • Very intuitive settings can be done by the assistance of the well configured user-interface consisting of a 5-inch LCD, ten-key, functions keys and others. Coupling modes are graphically shown, allowing the operator to select the desired mode and allows easy reference of settings when the test is in progress.
  • Emergency stop button
  • This button, easily accessible and placed on the front panel, enables the operator to stop the generation of the pulses anytime he/she desires. In addition to the high voltage power, the operator can turn off the EUT.
  • Safety interlock
  • A safely interlock is provided through the special design high voltage connector. The high voltage circuitry never be activated when the connector is not correctly positioned or not firmly locked.
  • Peak level monitor
  • The value of the actual peak amplitude is measured and shown for both voltage and current.