ISO 11452

ISO 11452 consists of the following parts, under the general title Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy:

  • — Part 1: General principles and terminology
  • — Part 2: Absorber-lined shielded enclosure
  • — Part 3: Transverse electromagnetic mode (TEM) cell
  • — Part 4: Harness excitation methods
  • — Part 5: Stripline
  • — Part 7: Direct radio frequency (RF) power injection
  • — Part 8: Immunity to magnetic fields
  • — Part 9: Portable transmitters
  • — Part 10: Immunity to conducted disturbances in the extended audio frequency range
  • — Part 11: Reverberation chamber

ISO 11452 There are 29 products.

Subcategories

  • ISO 11452-2 Shielded Room & Test Apparatus

    Rent, buy or lease ISO 11452-2 Shielded Room & Test Apparatus. The EMC Shop specializes in testing for electrical disturbances from radiated electromagnetic energy in car compents and sub assemblies.

    ISO 11452-2 Test Apparatus and Instrumentation

    ISO 11452-2 Shielded Room

    Diagram Test Setup of ISO 11452-2 Shielded Room with Test Apparatus

  • ISO 11452-4 BCI Test

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-4 BCI Test Equipment.

    ISO 11452-4 defines harness excitation methods (BCI testing) for road vehicles; the component test methods for electrical disturbances from narrowband radiated electromagnetic energy.

    Videos: ISO 11452-4 BCI Test Overview

  • ISO 11452-7 Direct RF Injection

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-7 Direct Radio Frequency (RF) Injection Test Equipment. 

  • ISO 11452-8 Magnetic Immunity

    Rent, buy or lease ISO 11452-8 Magnetic Immunity Test Equipment. The EMC Shop specializes in military and aerospace compliance testing.

  • ISO 11452-10 Immunity to Audio Frequencies

    The EMC Shop specializes in automotive radiated and conducted emissions and susceptibility testing. Rent, buy or lease ISO 11452-10 Immunity Test Equipment to Audio Frequencies. 

    Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 10: Immunity to conducted disturbances in the extended audio frequency range

    ISO 11452-10:2009 specifies a conducted voltage test method and procedure for determining the immunity of electronic components of passenger cars and commercial vehicles, regardless of the propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The method is applied to each individual device under test (DUT) lead and is applicable to all power and output leads, as well as low frequency analogue leads. The method is particularly useful in evaluating DUTs with acoustic or visible display functions.

    The disturbances considered in ISO 11452-10:2009 are limited to continuous narrowband electric voltage waveforms.

  • Stripline Antennas for Radiated Immunity

    Strip Lines are made for the generation of homogeneous electromagnetic fields and specified in ISO 11452-5 and EU guidelines 95/94. The strip lines can be used for testing of electrical/electronic submodules (EUB) and their associated cables.

per page
Showing 13 - 24 of 29 items
    • Rentals Ship Immediately
    • Order online now
    • Frequency: 10 kHz – 500 MHz
    • Internal diameter: 40 mm
    • External diameter: 98 mm
    • Height: 38 mm
    • ISO 11452 Testing
    In Stock
    Request Quote/More Info
    • 10 kHz – 500 MHz Frequency
    • For laboratory and field testing
    • RF current range is 50 amperes CW and 100 amperes peak pulse with a duty cycle of 0.1
    • Maximum primary powerline current is 350 amperes from DC – 400Hz
    • ZtΩ1: 8
    • dBΩ1: 18
    • DC to 400 Hz: 350 amperes
    • Peak Pulse Current2 : 100 amperes
    In Stock
    Request Quote/More Info
    • Most compact equipment for ripple noise on ac/dc supplies and magnetic fields
    • Built-in LF signal generator
    • Built-in LF amplifier
    • Built-in LF transformer 2:
    • Built-in frequency-selective voltage and current meter
    • Built-in load resistors
    • Automatic self-calibration
    • Frequency Range: 10 Hz - 250 kHz
    In Stock
    Request Quote/More Info
    • Integrated signal generator 80 MHz to 6 GHz
    • Integrated RF switch network
    • Integrated 3 freely configurable pulse modulators (1 μs to 200 s) for radar pulse profiles
    • Multiple EUT monitoring options
    • 3.5“ TFT color display
    • Safety interlock function
    • Remote control via USB, RS232 or LAN
    In Stock
    Request Quote/More Info
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    Typically In Stock
    Request Quote/More Info
  • In Stock
    Request Quote/More Info
    • Complete kit for ISO 11452-4 EMC Testing
    • Test methods include
      • Bulk Current Injection (BCI)
      • Tubular Wave Coupler (TWC)
    In Stock
    Request Quote/More Info
    • 100 kHz to 200 MHz frequency range
    • Multi standard design
    • 150 A max output current
    • Suitable also for DC lines
    • Large baseplate for optimal grounding
    • Robust, compact construction
    • Screw terminals for safe wiring
    • Meets the requirements of several standards including CISPR 16-1-2, CISPR 25,
    • ISO 11452-2/4/5, ISO 7637-2, MIL-STD-461F, DO-160, ED-14G
    Typically Stocked
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 80 W, 150 kHz to 230 MHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
    • Integrated signal generator 9 kHz to 1 GHz
    • 3 power meter inputs 9 kHz to 1 GHz
    • Integrated power amplifier module for different applications
    • Multiple EUT monitoring options
    • Optional built-in amplifier up to 75 watts (150 kHz - 230 MHz)
    • Meet IEC 61000-4-6,  IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 
    • Meet Mil-STD 461 CS114
    In Stock
    Request Quote/More Info
    • Rent the Teseq CIP 9136A BCI Probe
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    Typically In Stock
    Request Quote/More Info
    • Rentals ship immediately
    • Monthly Rate Price
    • Frequency Range 10 kHz - 1000 MHz
    • Power Rating 100 Watts
    • 40 dB
    • BNC Type Female Connector
    • SMA Type Female Connector
    In Stock
    Request Quote/More Info
Showing 13 - 24 of 29 items