MIL-STD-461 CS117

CS117 Purpose

Conducted susceptibility, lightning induced transients, cables and power leads.

Military Standard 461 Version G's new section CS 117 requires multiple stroke surge testing using a lightning transient generator. This requirement is similar to the well established RTCA/DO-160 Section 22 lightning immunity test standard.

Test Equipment

The test equipment shall be as follows:

a. Lightning transient generator

b. Injection Transformers

c. Oscilloscope

d. Current monitor probes

e. Attenuators, 50 ohm, as needed on current monitor probes

f. Voltage monitor probes, high impedance

g. Monitor loop, low impedance wire loop

h. Calibration loop, low impedance wire loop

i. Capacitor, >28,000 µF for DC power inputs

j. LISN

Get Application Support, Pricing, Lead Time and More: Contact Form

MIL-STD-461 CS117 There are 31 products.

per page
Showing 25 - 31 of 31 items
    • Waveform Output:
      • W2
      • W3
      • W6
    • PIN Injection Test
    • Cable Bundle Test (single stroke & multiple stroke)
    • RTCA DO-160 Section 22 Compliant
    In Stock
    Request Quote/More Info
  • In Stock
    Request Quote/More Info
    • Sample Rates Up to 5 GS/s on All Channels
    • 10 Megasample Record Length on All Channels
    • 3,700 wfms/s Maximum Waveform Capture Rate
    • Built-in Ethernet Port



    In Stock
    Request Quote/More Info
    • Frequency range 2 MHz to 500 MHz
    • Maximum input power 200 watts (see note)
    • Maximum input current 50 Amperes
    • Maximum time at full power 30 minutes

    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Frequency range: 1 kHz - 200 MHz
    • Transfer impedance (ZT): .001
    • Continuous signal current (CW): 50 A

    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Frequency range: 10 kHz to 500 MHz
    • Transfer impedance (ZT): 1.0 to 5.0 Ω above 300 kHz
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 40 A
    • Maximum power current: 200 A DC to 400 Hz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Modular design 
    • Single rack portability 
    • Programmable single stroke, multiple stroke, multiple burst waveforms 
    • Pin injection, cable bundle injection, ground injection up to Level 3 
    • Self-contained microprocessor control 
    • LCD system display
    • lightning induced transient susceptibility testing
    • requirements of RTCA/DO-160E/F/G Section 22 are met at Levels 1 through 3
    In Stock
    Request Quote/More Info
Showing 25 - 31 of 31 items