EMC Probes

Quick Links

Information

EMC Probes

 

Bulk Current Injection Testing         EMC/EMI Testing Services         Rent EMC Test Equipment          EMI Current Probes

 

Monitor high power, radiated fields or identify susceptible areas with a wide variety of probes for broadband monitoring or frequency specific points.

 

 Get Application Support, Pricing, Lead Time and More: Contact Form

 

CURRENT PROBES

 

Current probes required by various EMI specifications (such as MIL-STD-461/2) are toroidal transformers designed to measure RF currents on active power lines or other conductors.

 

INJECTION PROBES

 

Specifications require the injection of large high frequency currents into cable bundles and individual wires, using inserted secondary toroidal transformers placed around the conductors being tested.

 

Bulk current injection probes are available in two styles:

 

1. Fixed window style where the wire(s) under test must be passed through the window.

2. A split toroidal design where the probe can be opened and clamped over the wire(s) under test.

 

RF FIELD PROBES

 

Radio frequency field probes capable of measuring RF energy over a wide range of field strength and frequency.

EMC Probes There are 55 products.

Subcategories

  • EMI Current Probes/Monitors

    EMI Current Probes/Monitors are broadband RF devices, used to monitor current on data and power lines. While The EMC Shop stocks and uses them for EMC applications, many engineers will use them during product design and for other general testing purposes.

     

    Typically used in tantum with bulk current injection (BCI) probes. A broadband EMI current probe is used downstream to evaluate and monitor changes in characteristics once a low level RF/high frequency current was injected into the line or cable bundle. Typical applications include Mil-STD-461 CS101, CS102, RTCA-DO-160 and EN/IEC 61000-4-6.

     

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • Near Field Probes (E & H)

     

    Rental Information          ISO 17025 Lab          BCI Test Equipment            EMC Test Tables

     

    Near field probes are used to find vunerabilities in product. Using frequency specific E-field or H-field probes and an EMI analyzer, it will be easy to physically locate electromagnetic emissions in your product.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • Robotic Near Field Scanners

    Rent, buy or lease Robotic Near Field Scanners. The EMC Shop specialiles in RF and thermal characterization and measurement analysis.

  • EUT Transient Monitors

    Monitor conducted transients through PCB pins, review waveforms once passed through your device under test. Probes can monitor EFT and ESD events. The EMC Shop stocks EUT Transient Monitors for immunity generators.

per page
Showing 25 - 36 of 55 items
    • capable of measuring pulse transients with risetimes of 800 picoseconds
    • 3 amperes of CW and 100 amperes of peak pulse
    • 350 amperes of DC – 400 Hz
    • laboratory and field testing
    Typically In Stock
    Request Quote/More Info
    • 2 MHz - 40 GHz, 10 - 1000 V/m
    • Measures modulated electric fields, CW electric fields
    • Ortho angle mount & adapter foot provided for ease of mounting
    • Correction factors for frequencies included in each kit
    • Glass fiber optic cable can be up to 100m long
    • Laser powered, allowing for continuous operation without recharging/battery replacement
    In Stock
    Request Quote/More Info
    • 10kHz - 400MHz Frequency
    • Used for BCI testing in accordance
    • With automotive specifications like SAE J15447
    • CW input power rating is 100 watts for 30 minutes
    Typically In Stock
    Request Quote/More Info
    • Frequency Range:
      • H-Field Loop: 9 kHz - 5 GHz
      • E-Field Broadband: 50 kHz - 5 GHz
      • E-Field Fine Tip: 100 kHz - 5 GHz
      • Contact Tip: 400 Hz - 5 GHz
    • Lightweight - Easy to use and handle
    • Small Size - Allows easy access to corners
    • Sensitive to Tip Position - Ease of pinpointing source
    • Immune to Hand Position - For repeatable results
    • Optional preamplifier

    $595.00
    Typically In Stock
    Request Quote/More Info
    • 9 kHz to 30 MHz frequency range
    • CISPR 16-1-2 compliant
    • Suitable for lines up to 1000 Vac - 1500 Vdc
    • 30 or 35 dB insertion loss
    • Interchangeable, robust contact tip and alligator clip
    In Stock
    Request Quote/More Info
    • 10 kHz – 1 GHz Frequency
    • Used for BCI testing in accordance
    • With automotive specifications like SAE J15447
    • Useable frequency range is 100 kHz – 1300 MHz
    • With an insertion loss of less than 7 dB from 700 kHz to 500 MHz
    • Input power rating is 100 watts for 30 minutes
    Typically In Stock
    Request Quote/More Info
  • Quick view
    $409.00 Monthly
    • Frequency Range: 1 MHz - 1 GHz
    • Max Current: 200 Amps DC to 60 Hz, 20 Amps CW (50 Amps Pulse)
    • Transfer Impedance: 24 dBΩ
    • Aperture: 1.2" (32 mm)
    $409.00
    In Stock
    Request Quote/More Info
    • Frequency: 10 kHz – 400 MHz
    • Input Power rating: 100 watts
    • Less than 9 dB insertion loss between 10 kHz – 400 MHz
    • Ideal for ISO 11452-4, MIL-STD-461 CS 114
    Typically In Stock
    Request Quote/More Info
    • Frequency Range: 10 KHz - 300 MHz
    • Transfer Impedance: -25 to 1 dBW
    • Current:  350 Amps Max
    • Individually Calibrated
    • FCC, MIL-STD, VDE and TEMPEST Testing
    • Rugged Construction
    Typically In Stock
    Request Quote/More Info
    • Order online now
    • Rentals Ship Immediately
    • Locate emission “hot-spots”
    • Check on mechanical screening performance
    • Isolate faulty components
    • A diagnostic “tool kit” for use in both electrical and mechanical environments
    • 3 hand held probes (two magnetic, one electric)
    • 30dB pre-amplifier, power adaptor and check jig
    In Stock
    Request Quote/More Info
    • Measure conducted emissions from 10 KHz to 150 MHz
    • Capable of measuring pulse currents up to 100 amperes
    • Individually Calibrated (Transfer Impedance calibration included)
    • High Current Capability (100 Amps)
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis

    To Purchase AH Systems BCP-611

    Typically In Stock
    Request Quote/More Info
    • 10 kHz – 400 MHz Frequency
    • Injection Probe Calibration Fixtures
    • Part of the test equipment required by most of the Bulk Current Injection test procedure specifications
    • Calibration fixture allows the user the quickly
    • Easily calibrate the injection probe prior to performing compliance testing
    In Stock