AH Systems BCP-614 Probe to Measure Conducted RF Currents, 10 KHz - 300 MHz

New

  • Frequency Range: 10 KHz - 300 MHz
  • Transfer Impedance: -25 to 1 dBW
  • Current:  350 Amps Max
  • Individually Calibrated
  • FCC, MIL-STD, VDE and TEMPEST Testing
  • Rugged Construction

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Specifications

Frequency Range10 KHz - 300 MHz
Standards MetIEC 61000-4-6; IEC 60601-1-2, Mil-STD-461 CS 114
RF ConnectorN-Type (female)
Current Rating350 Amps
Application/Test TypeConducted and Radiated Susceptibility Testing
Aperture2.6" (66 mm)
Dimensions4.27" (134 mm)
Transfer Impedance-25 to 1 (dBohm)
Weight5.5 lb.'s (2.5 Kg)

Test Equipment Description

Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-614 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other 50 ohm impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables.

For ease and convenience of performing conducted measurements, all of our current probes utilize the split type clamp-on design. Small and lightweight, each Current Probe is manufactured to exacting standards, thus insuring repeatable performance.

AH Systems BCP-614 Features:

Frequency Range: 10 KHz - 300 MHz

Transfer Impedance: (dBohm) -25 to 1

Max Primary Current: (DC - 60 Hz) 350 Amps

Max Primary Current: (DC - 400 Hz) 350 Amps

Max Primary Current: CW 1.75 Amps

Peak Pulse Current: 100 Amps

Connector: N-Type, Female

Physical Dimensions:      

Aperture: 2.6" (66 mm)

Diameter: 4.27" (134 mm)

Weight: 5.5 lb.'s (2.5 Kg)