New

  • V-LISN
  • (9) 150 kHz - 100 MHz
  • 50 µH + 5 Ohm || 50 Ohm
  • 70 (100) A
  • 50 Hz AC 250 V
  • Two Path
  • Mil. Std. 461/462

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The main application of the V-LISN NNBL 8226-2 is the measurement of conducted emissions according to MIL-STD-462D, MILSTD- 461E, MIL-STD-461F and older versions of CISPR 16. In opposite to newer CISPR versions MIL has no requirements regarding the phase of the impedance or the decoupling between mains and DuT side of the LISN. The EuT is connected to the wing terminals at the front panel, the EMI-Receiver to the BNCconnector of the path to be measured. The other BNC-output is terminated with the supplied 50 Ω termination.

Application:

The main application of the V-LISN NNBL 8226-2 is the measurement of conducted emissions according to MIL-STD-462D, MILSTD-461E, MIL-STD-461F and older versions of CISPR 16. In opposite to newer CISPR versions MIL has no requirements regarding the phase of the impedance or the decoupling between mains and DuT side of the LISN.

The EuT is connected to the wing terminals at the front panel, the EMI-Receiver to the BNCconnector of the path to be measured. The other BNC-output is terminated with the supplied 50 Ω termination.

Schwarzbeck NNBL 8226-2 Specifications
Frequency Range(0.009) 0.15 - 30 (100) MHz
Max. cont. current70 A
Max. current (limited time)100 A
Max Voltage (DC)500 V
Max. Voltage (AC 50/60 Hz)250 V
Max. Voltage (AC 400 Hz)140 V
Impedance(50µH + 5 Ω) || 50 Ω (+/- 20 %)
DC-Resitance mains-EuT
EuT ConnectorsWing terminals
Dimensions220 x 320 x 260(+2x35) mm
Weight6.5 kg