Used GTEM Cells

Quick Links

Information

Viewed products

ETS Lindgren 5407 GTEM Test Cell View larger

ETS Lindgren 5407 GTEM Test Cell

Used

  • For all Phases of EMC Testing
    • Design Qualification
    • Pre-Compliance
    • Full Compliance IEC 61000-4-3 ANSI C63.4
  • New Sizes, Lower Price
  • 25x25x25 cm3 or 40x40x40 cm3EUT Test Volumes
  • For All Phases of EMC Testing:
    • Design Qualification
    • Pre-Compliance
    • Full Compliance
    • Post Production
  • For Full Compliance Demonstration of:
    • IEC 61000-4-3, EN 61000-4-3,
    • MIL-STD 462, ANSI C63.4,
    • EN 55022 and VDE 0871
  • Reduces Test Time
    • ≈8:1 for RE (vs. OATS)
    • ≈2:1 for RI (vs. chamber)

More details

Request Quote/More Info

PDF Downloads

Manual

ETS Lindgren 5400 Series

PDF Downloads (1.54M)

Test Equipment Description

ETS-Lindgren's Model 5407 GTEM!™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber.

ETS-Lindgren's Model 5407 GTEM! Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle. Beginning with design qualification testing and moving through to pre-compliance testing, full-compliance testing and production sampling, the model 5407 is a time saving device for your test lab. A typical radiated emissions test (10,000 point scan) can be completed in 15 minutes or less, while a typical radiated immunity test can usually be completed in half the normal time.

The GTEM! Test Cell is based on experience, not experimentation. Originally developed in the EMC Baden (Switzerland) Labs of ABB, the cell has been accepted in the EMC community for more than 10 years, and is field proven daily at more than 400 installations worldwide. Measurements made with a GTEM! Test Cell are accepted for final compliance demonstration by the FCC for Part 15 & 18 radiated emissions testing, and comply with IEC 61000-4-3 Annex D for immunity testing. The GTEM!'s unique tapered shape, offset septum, resistive termination network and absorber-lined back wall remove performance limitations of TEM cells and boxy enclosures. Electromagnetic wave and RF current termination are smooth and controlled. Field uniformity is +/- 3 dB up to 1 GHz, and +/-4 dB above 1 GHz.

Electrical Specifications
Feed Connector Typecw 7/16 DIN to N Adapter
Field Uniformityf £ 1 GHz, 0 -6dB
Frequency9 kHz to 5 GHz (RE)1; DC - 20 GHz (RI)2
Input Impedance50 Ω
Maximum CW Input3200/500W
Shielding Effectiveness10 kHz to 1 GHz From Internal E-Fields 80 dB min
VSWR MaximumAll Other Frequencies £ 1.50:1; Characteristic Frequencies £ 1.75:1
VSWR Typical All Other Frequencies 1.301; Characteristic Freq4 1.75:1
1 Measurement Range (Where Correlation to OATS is Established)3 Measurement - 3 Input GTEM-OATS Correlation Algorithm, 30 MHz to 5 GHz
9 Measurement - 9 Input GTEM-OATS Correlation Algorithm, 9 kHz to 5 GHz
2Low Input VSWR to f£ 20 GHz Available 
3500W with Optional Blower 
4Characteristic frequencyThe frequency at which cross-over between the two terminations (the resistor load boards and the RF absorber) occurs.
Physical Specifications
Door Dimension Primary (H)747 mm (29.41 in)
Door Dimension Primary (W)686 mm (27.01 in)
Door Dimension Secondary (H)385 mm (15.16 in)
Door Dimension Secondary (W)460 mm (18.11 in)
Highest Accuracy Transverse Test Surface in Center of Cell (H)5250 mm (9.84 in)
Highest Accuracy Transverse Test Surface in Center of Cell (W)5350.0 mm (13.78 in)
Maximum Recommended Transverse Test Surface in Center of Cell (H)6500.0 mm (19.69 in)
Maximum Recommended Transverse Test Surface in Center of Cell (W)6560 mm (22.05 in)
Maximum Septum Height7760 mm (29.92 in)
Outer Cell w/Base Dimension(H)82.1 m (6.89 ft)
Outer Cell w/Base Dimension(L)4.0 m (13.12 ft)
Outer Cell w/Base Dimension(W)2.2 m (7.22 ft)
Approximate Cell Weight500.0 kg (1,102.30 lb)

5From quasi-static E-Field with H=1/3 Septum Height and W=1/3 Septum Width
6From quasi-static E-Field with H=2/3 Septum Height and W=2/3 Septum Width
7Measurement Taken at Rear of Test Volume
8Contact you ETS-Lindgren Representative for Dimensions without Base

Other Specifications
  • Two AC Receptacles
  • Absorber Material
  • Three N-type Connectors
  • One Fiber Optic Penetration
  • Individually Characterized with Results of TDR and VSWR Tests
  • Manual Emissions Correlation Software Available Upon Request
  • Ships Disassembled (Customer will need to provide manpower and specific tools for installation. Working supervisor for installation is provided; outside North America, call factory.)
  • 7/16" DIN to Type "N" Adapter
  • Primary Door 68.6 cm x 74.7 cm (27 in x 29.1 in) Clear Opening
  • Mobile Base with Locking Casters
  • One 20 AMP, 2 Line Filter
  • Manual 

Associated EMC Test Equipment

2 other products in the same category: