MIL-STD-461 CS115

CS115 Purpose

Conducted Susceptibility, bulk cable injection, impulse excitation

This test procedure is used to verify the ability of the EUT to withstand impulse signals coupled onto EUT associated cabling.

Test Equipment

The test equipment shall be as follows:

a. Pulse generator, 50 ohm, charged line (coaxial)
b. Current injection probe
c. Drive cable, 50 ohm, 2 meters, 0.5 dB or less insertion loss at 500 MHz
d. Current probe
e. Calibration fixture: coaxial transmiss
ion line with 50 ohm characteristic impedance,
coaxial connections on both ends, and space for an injection probe around the center
conductor.
f. Oscilloscope, 50 ohm input impedance
g. Attenuators, 50 ohm
h. Coaxial loads, 50 ohm
i. LISNs

Get Application Support, Pricing, Lead Time and More: Contact Form

MIL-STD-461 CS115 There are 27 products.

per page
Showing 25 - 27 of 27 items
    • Frequency range: 1 kHz - 200 MHz
    • Transfer impedance (ZT): .001
    • Continuous signal current (CW): 50 A

    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Frequency range: 10 kHz to 500 MHz
    • Transfer impedance (ZT): 1.0 to 5.0 Ω above 300 kHz
    • Output load impedance: 50 + j 0 Ω
    • Continuous signal current (CW): 40 A
    • Maximum power current: 200 A DC to 400 Hz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Single generator output for CS114, CS115 and CS116 tests allowing remote test automation
    • Automatic calibration for each test and for the full test frequency range
    • Automatic configuration of the measurement equipment settings
    • Built-in scroll-down menus for selecting test equipment and components
    • Test and calibration reports automatically generated
    In Stock
    Request Quote/More Info
Showing 25 - 27 of 27 items