Conducted Emissions

 

Evaluate your DUTs line outputs (power and data) for compliance per FCC, UL, MIL-461, DO-160 and any other test standards. A conducted emissions test setup is done with a few pieces of equipment and can be accomplished quickly by novice engineers. Having an appropriate and properly grounded test setup ensures consistent and reliable measurements when evaluating your products conducted emissions. The EMC Shop is an ISO 17025 accredited company, stocking all the equipment to test conducted emissions.

 

Application Overview - Conducted Emissions Testing

 

Get Application Support, Pricing, Lead Time and More: CONTACT FORM

EMC Conducted Emissions Test Setup

EMC Conducted Emissions Setup

Conducted Emissions There are 64 products.

Subcategories

  • Analyzers, Receivers and Scopes

    Most any signal or spectral analysis unit can be used to evaluate the quality of your electrical components and DUT's. Quasi peak detection and EMI filters are offered as options by many manufacturers. EMI Receviers and EMC analyzers have the required hardware and software to help identiry problem areas in both conducted and radiated applications, saving time on pre-certifciation and saving money but better identifing issues that may cause failure at the certification lab.

  • Impedance Stabilization Networks (Power and Data Lines)

    Impedance Stabilization Networks  also known as Artificial Mains Networks are the most common transducer to perform conducted emission testing. For testing electrical power lines a Line Impedance Stabilization Network (LISN) is required. To test data lines an Impedance StabilizatioN Network (ISN) is used.

  • Transient Limiters

    Used between the LISN and measuring device such as an EMI receiver or a spectrum analyzer to protect the unit from high voltage spikes. Most transient limiters are spec'd to meet commerical and military conducted emissions standards (9 kHz to 30 MHz)

  • Preamplifiers

    Used inbetween close field probes and the measuring device (Spectrum analyzer or EMI receiver) to maximize performance of the probes and help identify problem areas while taking real time measurements.

  • Probes and Clamps

    Close field probes, current probes, voltabe probes and abosrbing clamps are scondary components required in some commercial and military & aerospace conducted emissions standards. The EMC Shop is an ISO 17025 accredited company with inventory of many electromagnetic probes and clamps for conducted emissions testing.

  • Accessories

    Conducted Emissions Accessories

  • Turnkey Bundles

    Rent, buy or lease turnkey test equipment bundles for conducted emissions testing to FCC, MIL-STD and more. The EMC Shop specializes in emissions test, pre-certification and compliance.

per page
Showing 49 - 60 of 64 items
    • Rigol DSA710 100kHz to 1GHz Spectrum Analyzer
      • 100kHz to 1GHz Frequency Range
      • Displayed average noise level (DANL) <-155dBm/Hz typ. with preamplifier on
      • Minimum resolution bandwidth (RBW) 100Hz
      • Phase noise <-80dBc/Hz @10kHz offset
      • Level measurement uncertainty <1.5dB
      • 8" (800 x 480) high-definition display
      • Linear and logarithmic frequency axis
    • EMI-DSA800
      • For DSA800 Series Models
      • EMI Filter & Quasi-Peak Detector Kit
      • Option can be added by a software key
    • NFP-3
      • 30MHz to 3GHz Frequency Range
      • One set includes four types of probe, provides optimizing sensitivity and resolution
      • Minimum resolution: 2mm; able to capture near field radiation of single circuit line
      • Applicable for electromagnetic leakage testing inside the cable
    • S1210 EMIs
      • Introduces the workspace concept - Manage multiple measurements easily
      • 'Demo' mode included - Trial the software without an instrument and a licence
    In Stock
    Request Quote/More Info
    • FPC1000 Low-Cost Spectrum Analyzer for Emissions Testing
      • Frequency range: 5 kHz to 1 GHz, Upgradable to 2 GHz or 3 GHz
      • Resolution bandwidth settings down to 1 Hz
      • 10.1" WXGA (1366 x 768 pixel) display
      • Wi-Fi-enabled w/ remote control (included)
      • Easy virtual control w/ iOS/Android/PC
      • Low noise floor / High max. input power
      • Receiver mode for EMI debugging on circuit boards, integrated circuits, cable shielding, etc.
    • HM6050-2 Line Impedance Simulation Network
      • Frequency range from 9 kHz to 30 MHz
      • Built-in transient limiter
      • Artificial hand connector
    • HZ540 Near Field Probes
      • Frequency range from 100 kHz to 1/3 GHz
      • Probes included (1 × Electrical Field Probe, 1 × Magnetic Field Probe, 1 × High Impedance Probe)
    • EMC PreCom
      • EMC Precompliance Software (EMC PreCom) -- EMI module part of the HMExplorer software for conducting precompliance measurements (only with HO720 USB/RS-232 or the optional HO732 Ethernet/USB interface)
    In Stock
    Request Quote/More Info
    • FPC1000 Low-Cost Spectrum Analyzer for Emissions Testing
      • Frequency range: 5 kHz to 1 GHz, Upgradable to 2 GHz or 3 GHz
      • Resolution bandwidth settings down to 1 Hz
      • 10.1" WXGA (1366 x 768 pixel) display
      • Wi-Fi-enabled w/ remote control (included)
      • Easy virtual control w/ iOS/Android/PC
      • Low noise floor / High max. input power
      • Receiver mode for EMI debugging on circuit boards, integrated circuits, cable shielding, etc.
    • Teseq ISN T8 Impedance Stabilization Network (ISN) for Unscreened Balanced Pairs
      • For use with one, two, three, or four unscreened balanced pairs
      • Refers schematic circuit example in CISPR 22/32 Figure D.3/G.3
      • Intended for connection to cable category 3 and 5
      • 1000BaseT and PoE application
      • Changeable pin-arrangements with RJ11 and RJ45
    In Stock
    Request Quote/More Info
    • 9kHz-30MHz
    • V LISN
    • CISPR 16-1-2 ANSI C63.4 FCC, ETS, VCCI and VDE, MIL461E/F
    • N type /BNC Connector option
    In Stock
    Request Quote/More Info
    • Price is for a pair of LI-550A LISN's
    • Fully compliant to CISPR 16-1-2 / CISPR 25
    • "Air-core" inductors to prevent saturation
    • Provides a near 1:1 (<0.5 dB insertion loss) 50Ω coaxial measurement port (type-N)
    • Provides a defined, stable, impedance to the Equipment Under Test (EUT)
    • Individual Calibration Included
    • Three Year Warranty
    Typically In Stock
    Request Quote/More Info
    • 10 kHz to 400 MHz Frequency Range
    • Price is for a pair of LI-125A line impedance stabilization networks
    • Frequency range of 10 kHz to 400 MHz
    • Fully compliant with DO-160/ MIL-STD 461
    • “Air-core” inductors to prevent saturation
    • Individual Calibration Included
    • Three-Year Warranty
    Typically In Stock
    Request Quote/More Info
    • Price is for a pair of LI-125A line impedance stabilization networks
    • Frequency Range: 150 kHz to 30 MHz
    • Integral Transient Limiter/10 dB Attenuator with
    • ON/OFF (bypass) Switch
    • Fully Compliant with CISPR 16-1-2/ANSI C63.4
    • Dual-Conductor Network with Universal Power
    • Receptacle to accept any EUT Plug
    • 20 Amps Current Handling Capability
    • Three-Year Warranty
    Typically In Stock
    Request Quote/More Info
    • Purchase Com-Power ISN-T8 here
    • Frequency Range: 150 kHz to 30 MHz
    • For Unshielded Telecomunication Lines 1 to 4 balanced pairs
    • Complies with CISPR 16-1-2, CISPR 22/32
    • Individual Calibration Included
    $410.00
    Typically In Stock
    Request Quote/More Info
    • Rentals ship immediately
    • Monthly Rate Price
    • Current ISO 17025 Calibration Provided
    • Meets CISPR 16-1-1: 2010 and MIL-STD-461
    • Frequency Range: 20 Hz - 40 GHz
    • Configuration Includes:
      • B10: External Generator Control via GPIB
      • B18: Removable Hard Disk
    In Stock
    Request Quote/More Info
    • 9kHz-30MHz 
    • V LISN
    • CISPR 16-1-2 ANSI C63.4 FCC, ETS, VCCI and VDE, MIL461E/F
    • N type /BNC Connector option
    Call for Availability
    Request Quote/More Info
    • Fully compliant to CISPR 16-1-2 / ANSI C63.4
    • "Air-core" inductors to prevent saturation
    • Provides a near 1:1 (<0.5 dB insertion loss) 50Ω coaxial measurement port (type-N)
    • Provides a defined, stable, impedance to the Equipment Under Test (EUT)
    • Individual Calibration Included
    • Three Year Warranty
    Typically In Stock
    Request Quote/More Info
    • For asymmetric disturbance measurements on PLT devices
    • Frequency range 1.6 to 30 MHz
    • LCL >55 dB
    • Conform with EN 50561-1
    • Supplied with Coupling Unit
    $2,460.00
    In Stock
    Request Quote/More Info
Showing 49 - 60 of 64 items