3ctest Oscillatory Wave Simulators

Quick Links

Information

Viewed products

3ctest PAWG 100 Arbitrary Signal Generator View larger

3ctest PAWG 100 Arbitrary Signal Generator

New

  • Meet the tests as per ISO16750 (corresponding individual manufacturer standard)
  • Every oscillation channel has waveform arithmetic circuitry to output waveform with high resolution and accuracy
  • By software control with Ethernet, represent kinds of variation phenomenon easily and really.
  • Ensure the synchronization deviation among channels to be less than 1μs
  • Waveform data (CSV) received from oscilloscope can be output with high accuracy.

Application

  • Automotive

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The test waveforms in automotive become more and more complicated, and more attention are paid to vehicle or components. Normal waveform generator can’t meet these requirements, especially, multiple waveforms superposition during one test is needed, PAWG 100 arbitrary signal generator is the best solution.

  1. Multiple sequence oscillator
  • Signal output part is cordwood components, can be extended to max. 4 channels.
  • Can generate arbitrary waveforms: DC wave, ramps, sine, sweep frequency, exponential, frequency modulation/amplitude modulation sine wave, irregular and random arbitrary wave.
  • Can generate variation waveform with voltage and time axis
  • Can generate waveform timing sequence
  1. Software for generating arbitrary waveform

Using excellent GUI arbitrary waveform generation software, it can easily generate complex waveforms with repeated voltage, time scanning.

As per

  • BMW-(Airbag ECU)
  • BMW 600 13.0(Part 1)
  • Case New Holland ENS0310
  • Cummins 14269(982022-026)
  • BMW GS 95003-2
  • FAW Diesel ECU MY06.0(Rew.7)
  • BMW GS 95024-2-1(2010-01)
  • Chrysler CS-11809(2009)
  • DaimlerChrysler DC-10614
  • Many automobile manufacturers test standards
  • Ford ES-XW7T-1A278-AB
  • Audi(Reference vehicles)
  • Fiat 9.90110
  • Ford EMC-CS-2009.1
Technical Parameters
Number of Channels1ch~4ch, 2 or 4 optional
Synchronization accuracy among channelsThe synchronization time among each channel can be adjusted with unit 0.1μs, adjusting range: 0.1μs~100μs. The synchronization accuracy among channels can be kept to be less than 1μs at output terminal.
Waveform typeDC wave, ramps, triangle wave, sine, square wave, sweep frequency, exponential, frequency modulation/amplitude modulation, Oscilloscope storage data waveform, user’s self-defined waveform, irregular and random arbitrary wave
ParametersAmplitude, duration, frequency, DC offset, rectification, duty cycle, phase angle, trigger, noise
Amplitude and offset rampingStatic, linear, exponential
Frequency rampingStatic, linear, exponential, log(base 10)
Start/End phase angle0 ~ 360°in 1°step
RectificationNone, positive, negative, bridge rectification, programmable
Frequency range per channelOperate mode: 500kHz max. sine, square, triangle wave, etc, which include sweep frequency, amplitude, offset, phase angle and synchronization change among channels.

Direct internal storage mode: DC-500kHz arbitrary wave, 1MHz square wave
Waveform output rate25MSPS per channel
Frequency resolution0.001Hz
Rise/fall time≤100ns @20Vpp
Waveform voltage amplitude0~±10.00V
Drive capacity≥ 1 kΩ
Short circuitYes
File typeCSV, EXCEL, TXT
File waveform points16MB Max
Waveform data storageDynamic cache data storage: 1GB DDR3 NVDS: 32GB NAND FLASH
Segments of waveform1000 segments per waveform, each segment is composed of several kinds of waveforms
Segment duration100µs to 999hrs or infinite loop
Delay between segmentsNone
Test duration1ms~9999hrs, 1 to 99999 count, or infinite loop
Trigger oscilloscope outputA BNC socket 0-5V, setting trigger point at the arbitrary point of waveform generation software, monitoring the generated waveform by oscilloscope external trigger function
External control inputOne BNC socket 0-5V input, used for 1~4ch waveform external control
PC interfaceEthernet
Operating temperature range15°C-35°C
Operating humidity range45%-75%
Driving power supplyAC 90V-260V 50/60Hz 100VA
Dimension19’/4u
WeightApprox.10kg
For the future of modern testing equipment
Protection 
Voltage setting resolution1mV
Output accuracy
± (0.2% + 10mV)DC – 10 kHz
±1%10 – 100 kHz
± 2%100 – 350 kHz
± 5%350 – 500 kHz


AutoLab software

By self-developed AutoLab software, users can edit kinds of waveforms for waveform segment or test points. According to different requirement, users can regulate the waveform by advanced image tools, and recording waveforms by other way is also supported like oscilloscope capturing. All types of waveforms can be downloaded to PAWG 100. PAWG 100, APS and APG series must be matched together.

Associated EMC Test Equipment

11 other products in the same category: