The 3ctest TIS 700 Series for automotive transient unifies the capabilities of an EFT/Burst P3a/3b, micro pulse P1/2a and the required coupling network into one box. The TIS700 series are equipped to meet all international, car manufacturer specifications, and kinds of waveform modules can be customized as per user’s requirements. The current of built-in coupling network ranges up to 200A depending on the model. The built-in coupling network can be used and controlled by any unit of the LDS200 series, APG series and APS series to be the central EUT output port. Different simulators can be connected together via data bus and connected to PC via Ethernet to be a whole test system.
Standard:
Test connection:
Technical Parameters | |||
Micro Pulse Module P1 | |||
Test voltage | 3-600V | ||
Test voltage | Negative | ||
Rise time Tr | 0.5us - 1us 1.5us - 3us No load | ||
Duration Td | 50us 土20% no load 12us 土20% matching load 1ms 土20% no load 1ms 土20% 50 ohm matching load 2ms土20% no load 1.5ms土20% 10 ohm matching load 0.2ms 土20% no load 0.3ms 土20% no load 0.5ms土20% no load | ||
Source impedance | 2Ω,4Ω,10Ω,30Ω,50Ω | ||
Number of test | 1-9999 | ||
DUT voltage monitoring | 10:1 | ||
DUT current monitoring | 10A:1V | ||
Pulse interval | 0.2s-60s (the shortest interval depends on output voltage) | ||
Coupling mode | ICC,DCC(50us 土20% no load waveform) | ||
Micro Pulse Module P2a | |||
Test voltage | 3-150V | ||
Test voltage | Positive | ||
Rise time Tr | 0.5us - 1us 1.5us - 3us No load | ||
Duration Td | 50us 土20% no load 12us 土20% matching load | ||
Source impedance | 2Ω | ||
Number of test | 1-9999 | ||
DUT voltage monitoring | 10:1 | ||
DUT current monitoring | 10A:1V | ||
Pulse interval | 0.2s-60s (the shortest interval depends on output voltage) | ||
Coupling mode | ICC,DCC | ||
EFT/Burst Module P3a/3b | |||
Test voltage | 25-700V | ||
Polarity | P3b positive,P3a negative | ||
Rise time Tr | 5ns土30% into 50 ohm load 5ns土30% into 1,000 ohm load | ||
Duration Td | 150ns - 45/+45ns into 50 ohm load 150ns - 45/+45ns into 1,000 ohm load | ||
Source impedance | 50Ω | ||
Pulse number | 1-200 | ||
Burst interval | 50ms-999ms | ||
Pulse frequency | 0.1kHz-200kHz | ||
Test duration | 1s-50000s | ||
Coupling mode | CCC,DCC | ||
Output | Direct output | By 50Ω coaxial connector (for test connected to capacitance coupling clamp) | |
General Parameters | |||
Mains supply | AC 110/220V,土10%,45-65Hz | ||
Environment temperature | 15-35°C | ||
Relative humidity | 35%-85%RH(no condensing) | ||
Dimension | Output current 30A: 4U | ||
Output current 60A and 100A: 6U Output current 200A: 8U | |||
Weight | Approx. 20kg | ||
Trigger | Automatic, manual | ||
Network | Internal CDN 60V/30A current up to 200A | ||
Input | DUT supply | DC voltage from APS, APG or other DC source | |
Pulse 5,7 | TIS 700 network superimposing Pulse 5 and Pulse 7 | ||
Output | LDS200 input | Central DUT output port | |
Coaxial output port | To connect capacitance coupling clamp as per ISO7637-3 |