5 Line CDN

Quick Links

Information

Viewed products

EM Test (Lüthi) CDN M5 5-Line Coupling/Decoupling Network (L1+L2+L3+N+PE) - EMC Test Equipment View larger

EM Test (Lüthi) CDN M5 5-Line Coupling/Decoupling Network (L1+L2+L3+N+PE)

New

  • For 5 AC supply lines (L1/L2/L3/N/PE)
  • AE: 4mm safety lab connectors
  • EUT: 4mm safety lab connectors
  • AC: max. 3 x 750 Volts / 100 Amps
  • DC: max. 1,000 Volts /100 Amps
  • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)

More details

Typical Lead Time 4 - 6 Weeks

Request Quote/More Info

Specifications

Voltage Ratingup to 750 Volts AC and DC
Frequency Range150 kHz to 300 MHz (150 kHz - 80 MHz at high power)
Standards MetIEC / EN 61000-4-6
Mains & EUT ConnectionsAE: 4mm safety lab connectors EUT: 4mm safety lab connectors (high-current MC connectors for AE and DUT port on 75 Amp & 100 Amp models)
Current Ratingup to 100 Amps
Application/Test TypeCoupling/decoupling networks for Conducted immunity, mains AC power supply lines
RF Input Voltage30 V (Max)

Test Equipment Description

The EM Test (Lüthi) CDN M5 5-Line Coupling/Decoupling Network (L1+L2+L3+N+PE) is a configurable CDN allowable for AC power lines testing of L1/L2/L3/PE/N. Please specify configuration under CDN Power Capacity in the order box above.

Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines. 

For testing conducted RF immunity according to IEC 61000-4-6 and IEC / EN 60945 different types of CDN are required, depending on cable. Specific CDNs are also used for emission measurements according to CISPR 15 and EN 55015. 

EM Test (Lüthi) offers a wide selection of appropriate coupling / decoupling networks, and current probes and the associated accessories for standard-compliant calibration.

EM Test (Lüthi) CDN M5 Specifications:

  • For 5 AC supply lines (L1/L2/L3/N/PE)
  • AE: 4mm safety lab connectors
  • EUT: 4mm safety lab connectors
  • AC: max. 3 x 750 Volts / 100 Amps
  • DC: max. 1,000 Volts /100 Amps
  • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)

EM Test (Lüthi) CDN M5 Models:

  • CDN M5: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 1000V DC, 16A, 150kHz - 230MHz
  • CDN M5-32A: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 1000V DC, 32A, 150kHz - 230MHz
  • CDN M5-32A/750V: CDN for five mains supply lines (L1+L2+L3+N+PE), 3x750V AC, 1000V DC, 32A, 150kHz - 80MHz
  • CDN M5-75A: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M5-75A/750V: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x750V AC, 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M5-100A: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x400V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M5-100A/750V: CDN for five mains supply lines (L1+L2+L3+N+PE) 3x750V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port

Associated EMC Test Equipment

6 other products in the same category: