EN/IEC 61000-4-6

Quick Links

Information

Viewed products

Narda PMM COND-IS/10 RF Conductive Immunity Test System View larger

Narda PMM COND-IS/10 RF Conductive Immunity Test System

New

  • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
  • Meet IEC 61000-4-6 or MIL-STD-461 CS114
  • Easy to setup and use of software

More details

In Stock

Request Quote/More Info

Specifications

Frequency Range9 kHz to 230 MHz
Standards MetIEC 61000-4-6
Application/Test TypeCreate and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
Test RoutinesQuick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure
Input115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
Maximum Continuous Power10 W; 15 W from 150 kHz - 80 MHz
Impedance50 Ohms
ConnectorBNC Input, Output Type N(f)

Test Equipment Description

About Narda PMM COND-IS/10:

In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) “RF Conducted Immunity” compliance verification is definitely one of the easiest and less expensive to be performed “in house”, not requiring any special environment and normally involving a low power RF Amplifier. For this reason NARDA Italy has renewed its already well known as 6000S/10 RF Immunity System with components and test management software to follow and even overcome latest requirements from the Standard IEC/EN 61000-4-6.

The new “PMM Immunity Suite” software, accurately designed in terms of functions and user friendly approach, can manage the whole range of PMM components during both Test and Calibration processes, introducing the possibility of looking at the various monitoring tracks from generator and power meters (from field meter too in case of Radiated Immunity).

Cond-IS/10 system has been designed to provide all necessary components required for testing in accordance to IEC/EN 61000-4-6 with just one “package”, not losing modularity but still maintaining a very simple and cost effective solution. Operator can then only focus on testing, without worrying about collecting components and being sure they can properly work together automatically driven by a specifically designed software. The Cond-IS/10 system includes following standard components:

  • Generator 3010 , 9 kHz – 1 GHz, -107 to +10 dBm
  • Amplifier 6000N, 9 kHz – 230 MHz, 10/15 W
  • ATT-25W, 6 dB Attenuator, 25 W max
  • CDN M3-16, 3 lines 16 A each, calibrated at 1, 3 and 10 V levels
  • Cab-06, Cable Kit to fully connect the system
  • PIMS, PMM Immunity Suite software for Windows™ OS operated PCs

In case any different testing device should be required, it would always be possible to customize the system accordingly. More powerful amplifiers are also available upon request when a “Special”Test Level over 10 V should be achieved or when using an EM Clamp in conjunction with a Filtering Clamp; in this case the 6 dB Attenuator should be changed as well, according to the new max power level. As additional benefit, NARDA Italy Labs always provide the selected device (CDN, EM Clamp or Current Injection Probe) fully calibrated at 1, 3 and 10 V standard stress levels, together with the whole Cond-IS/10 system, i.e. including all RF cables and components belonging to the real testing condition.

Associated EMC Test Equipment

30 other products in the same category: