FCC Part 15

Quick Links

Information

FCC Part 15

FCC Part 15 regulates low power, unlicensed devices that could cause interference to the Amateur Radio Service and vice versa.

FCC Part 15 covers an assortment of electronic equipment that generates RF energy whether it's intentional, unintentional or incidental. Amateurs will need to consider Part 15 as it relates to digital devices, computers, low-powered, unlicensed transmitters, electrical devices and any other "generic" device that might generate RF in the normal course of its operation.

Rent, buy, or lease FCC Part 15 test equipment for radiated and conducted emissions measurements. The EMC Shop stocks calibrated equipment.

FCC Part 15 There are 44 products.

Subcategories

  • Cable Input Conducted Emissions

    Conducted spurious emissions that appear at the cable input to the device must meet the following criteria. The input shall be an NTSC video carrier modulated with a 10 IRE flat field with color burst at a level of 0 dBmV and with a visual to aural ratio of 10 dB. The aural carrier shall be unmodulated. The peak level of the spurious signals will be measured using a spectrum analyzer connected by a directional coupler to the cable input of the equipment under test. Spurious signal levels must not exceed the limits in the following table:

    • From 54 MHz up to and including 300 MHz–26 dBmV
    • From 300 MHz up to and including 450 MHz– 20 dBmV
    • From 450 MHz up to and including 804 MHz15 dBmV

    The average of the measurements on multiple channels from 450 MHz up to and including 804 MHz shall be no greater than -20 dBmV. Measurements shall be made with the receiver tuned to at least four EIA IS–132 channels in each of the above bands. The test channels are to be evenly distributed across each of the bands. Measurements for conducted emissions caused by sources internal to the device are to be made in a shielded RF room. Measurements for conducted emissions caused by external signal sources shall be made in an ambient RF field whose field strength is 100 mV/m.

    The EMC Shop specializes in RF testing and compliance equipment solutions. Contact us now to acquire test equipment to measure cable input conducted emissions according to FCC Part 15. 

  • RF Field Strength Meters

    The EMC Shop specializes in RF testing and conformance. Rent, buy or lease RF field strength meters for measurements as referenced to in FCC Part 15.5 (dd). 

  • FCC Line-impedance Stabilization Network (LISN)

    Measurements of radio frequency emissions conducted to the public utility power lines shall be performed using a 50 ohm/50 uH line-impedance stabilization network (LISN). NOTE: Receivers tested under the transition provisions contained in §15.37 may be tested with a 50 ohm/5 μH LISN.

    Rent, buy or lease FCC Line-impedance Stabilization Networks (LISN). The EMC Shop specializes in measurements of radio frequency emissions.

  • FCC Radiated Emissions

    The EMC Shop stocks turnkey test systems for conducting radiated emissions in a lab or isolating using a GTEM or RF Tent. Rent, buy or lease FCC Radiated Emissions test equipment. Antennas, Spectrum Analyzers, Transient limiters, near field probes and other accessories for EMC and FCC emissions testing.

per page
Showing 13 - 24 of 44 items
    • Meausurement up to 1300 V/m CW
    • Dynamic Range: 64 dB
    • Flatness: ±1 dB (1 MHz - 1 GHz), ±1.25 dB (1 - 2.45 GHz)
    • Isotropic Response: ±1 dB
    In Stock
    Request Quote/More Info
    • Measurement Range: 8 to 614 V/m
    • Dynamic Range: 37 dB
    • Flatness: ±1.25 dB
    • Isotropic Response: ±1 dB
    • Ideal for Satellite Communication, Leak Detection and Exposure Levels (Partially suitable for Radar Signals)
    In Stock
    Request Quote/More Info
    • Operation: 80 Hours on Full Charge 
    • Data Logging: 115 Point Scratch-pad Data Logging 
    • Recorder Out Level: 0 to 5 VDC Proportional to Full Scale Reading
    • Units of Measure: V/m, V2/m2, A/m, A2/m2, mW/cm2 (Probe Dependent)
    $1,800.00
    Out of Stock
    Request Quote/More Info
    • Broadband measurements DC - 60 GHz With RMS and isotropic field probes
    • Spectrum analysis DC - 400 kHz Real-time FFT
    • Weighted Peak Method (WPM) Real-time comparison in % with the selected limits
    • Assessments according to European Directive 2013/35/EU In accordance with international standards: ICNIRP, IEC, EN, IEEE, etc.
    • High performance GPS Integrated in the instrument
    • USB and Fiber Optic Communication PC software included
    In Stock
    Request Quote/More Info
    • Intelligent probe interface detects probe parameters
    • Fully automatic zero point adjustment
    • Memory for saving up to 5,000 measurement results
    • PC software for convenient data management
    • Voice recording for comments
    • Conditional logging: Measured value saved when a threshold value is exceeded
    Typically Stocked
    Request Quote/More Info
  • Quick view
    $650.00 Monthly
    • New - Old Stock
    • Intelligent probe interface detects probe parameters
    • Fully automatic zero point adjustment
    • Memory for saving up to 5,000 measurement results
    • PC software for convenient data management
    • Voice recording for comments
    • Conditional logging: Measured value saved when a threshold value is exceeded
    $650.00
    In Stock
    Request Quote/More Info
    • Intelligent probe interface detects probe parameters
    • Fully automatic zero point adjustment
    • Memory for saving up to 5,000 measurement results
    • PC software for convenient data management
    • Voice recording for comments
    • Conditional logging: Measured value saved when a threshold value is exceeded
    In Stock
    Request Quote/More Info
    • 150 kHz to 30 MHz Frequency Range
    • 32 Amps Current Rating
    • Fully Compliant with CISPR 16-1-2/ANSI C63.4
    • Remote Switching of Line Under Test
    • Four-conductor Network appropriate for both 3Ø Delta and Wye Power Configurations
    • Three-Year Warranty

    To Purchase Com-Power LI-3P-132

    In Stock
    Request Quote/More Info
    • Dual-line-V-LISN
    • Compliant to CISPR 16-1-2, MIL-STD-461, FCC Part 15, ANSI C63.4
    • Current up to 16 Amps
    • Frequency range 9 kHz to 30 MHz
    • Hand and remote operated
    • Massive grounding bars
    Typically In Stock
    Request Quote/More Info
    • Frequency Range: 9 kHz to 30 MHz
    • Current Rating: 16 Amps
    • Fully Compliant with CISPR 16-1-2/ANSI C63.4
    • Remote Switching of Line Under Test
    • Four-conductor Network appropriate for both 3Ø Delta and Wye Power Configurations
    • Three-Year Warranty
    In Stock
    Request Quote/More Info
    • Rentals Ship Same Day
    • Typ. configured w/ NEMA
    • Suitable for making FCC 15, VDE 0871, VDE 0875 and EN 55022 conformance measurements
    • Insulated Plug for Safer Power Connections
    • Earth Line Choke isolates EUT from RF ground while maintaining a safety ground
    • Calibrated to ANSI C63.4
    Typically In Stock
    Request Quote/More Info
    • Rentals Ship Same Day
    • Input Power up to 1000 Watts
    • Frequency coverage from 25 MHz - 2000 MHz
    • Emissions Testing
    • Immunity Testing to IEC 61000-4-3
    Typically In Stock
    Request Quote/More Info
Showing 13 - 24 of 44 items