ESD Simulators

Quick Links

Information

Viewed products

Schloder SESD 230 30 kV ESD Simulator

New

  • 30 kV AIR and CONTACT discharge
  • IEC 61000-4-2 (150 pF / 330 Ohm)
  • Battery or mains operation
  • Programmable automatic test runs
  • Predefined test levels acc. to the standard
  • Contact control for contact discharge
  • Displaying of the real discharge voltage at air mode
  • Counter mode with and without automatic polarity change

Carrying Case Includes (3,4 kg):

  • ESD Simulator
  • Battery Charger incl. Cable
  • Test tip air discharge and test tip contact discharge
  • Ground Cable
  • Manual

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Test Equipment Description

Schloder SESD 230 30 kV ESD Simulator

The ESD Simulator SESD 230 is suitable for performing EMC tests on systems in accordance with the standard IEC / EN 61000-4-2 (ESD test). Higher test levels can be set far beyond the standard limits. Depending on the test object and test setup, two test methods are to be used:

  1. Air Discharge
    In this case, the pulse is triggered by approaching the SESD 230 towards the DUT. The high voltage applied to the discharge electrode is discharged suddenly, resulting in a very broadband highfrequency interference spectrum. This in turn can lead to influences on the test specimens.

  2. Contact Discharge
    With this method, the probe of the generator is placed directly on the test object. The actual "impulse triggering" takes place via a relay contact and reduces the influencing factors such as approach speed, amplitude height, air humidity and temperature.
    Important: In the case of non-contacting (eg painted or oxidized surface), the impulses are not triggered. The display shows "No contact". This ensures that when triggering a discharge actually takes place.

The contact discharge is the favourite test method since it is most reproducible. Air discharges are used when contact discharges are not possible - e.g. at plastic housings. The test voltages defined for each test method are shown in the table below:

Test level
LevelVoltage
air discharge
Voltage
contact discharge
12 kV2 kV
24 kV4 kV
38 kV6 kV
415 kV8 kV
xmax. 30 kVmax. 30 kV

Typ. Shape of the Discharge Current
Schloder SESD 216 Typ. Shape of the Discharge Current

Performance feature

  • Contact control
    The simulator has a "Contact control". When testing "CON" touches the test tip the surface of the EUT. When not contacted, will be no triggering of the pulse. The display shows "No contact". This ensures that at contact discharge actually occurs a discharge.

  • Always ready to use
    The simulator operates on battery power. If the battery is empty, it can immediately be charged with the charger provided. Loading bar in the display indicate the charging status.
    No change of the battery required! (according to experience replacement battery are also empty if you need them).
Schloder SESD 230 Technical Data
Generator
Output voltage, adjustment via digital potentiometer
Test mode air discharge0,2 kV to 30 kV, 100V steps
Test mode contact discharge0,2 kV to 30 kV, 100V steps
Polarity of the output voltagePositive and Negative
Test modesAir- and Contact Discharge
Repetition frequency of the discharge pulses
Air dischargeSingle pulse or repeated *
*(frequency depends on the distance between the discharge electrodes and the examinant)
Contact dischargeSingle pulse, 0,1 Hz, 0,2 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz
Continuous operationPossible at air- and contact discharge
Holding time≥ 5 sec
Pre selectable counter1 - 9999
Discharge electrodesIn conformity to IEC / EN 61000-4-2
Energy storage capacity150 pF ± 10%
Discharge resistor330 Ohm ± 5%
Operation temperature range0 - 40° Celsius
Relative humidity0 - 60%
WeightApp. 1470 g
Power supply
Supply voltageIN: 100-240 VAC / 47-63 Hz;
OUT: 9 VAC / 3 A Weight: app 200 g

Associated EMC Test Equipment

3 other products in the same category: