Teseq GTEM-250 GTEM cell for Emissions and Immunity testing View larger

Teseq GTEM-250 GTEM cell for Emissions and Immunity testing

New

  • Suitable for EUT Approx. (200 x 200 x 150mm) (7.87 x 7.87 x 5.90in.)
  • Max EUT dimension for uniform-area: (83 x 83 x 83mm) (3.26 x 3.26 x 3.26in.)
  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification

More details

Request Quote/More Info

Test Equipment Description

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.

Specifications of the  Teseq GTEM-250:

ParameterValue
Max. septum height

250 mm

Septum height at marker position

217 mm

Dimension (LxWxH)

1.25 x 0.65 x 0.45 m

Weight

45 kg

Standard configuration:

  •  Desktop version
  •  Door on the right side, clear opening of 20 cm x 13 cm
  •  EUT BOX for free application
  •  Fan with power supply unit for countries EU, AUS, UK, US/JP
  •  Emission correlation tool (Windows software for manual input)
  •  Measurement report for TDR and VSWR
  •  Measurement report for input power requirements for 10 V/m (80 - 1000 MHz)
  •  Shipped assembled

Options:

  •  POW 250, extended version for 100 W RF-input power
  •  OPL 250, feed through for fiber optics
  •  Special filter solutions
  •  Endwise version
  •  ETV 250, extended test volume for GTEM 250 in direction to the input section, lowest septum height of 100 mm, max. EUT size of 30 x 30 x 30 mm at 100 mm septum height
  •  SHD 1, additional door, clear opening of 20 cm x 13 cm
  •  SHW 250, shielded window, 12 cm x 7 cm
  •  Manipulator solution
  •  Test house software for emission and immunity testing