Viewed products
 
 7.5GHz ~ 50GHz (up to 7.5GHz ~...
New
Warning: Last items in stock!
Availability date:
GTS creatively put forward a Physics based Source Reconstruction and Mid-field Measurement method. Based on the method, MieZone1600 can perform:
MieZone1600 strictly controls every part of the system (quiet zone <-40dB; narrow beam and low X-polar ratio probe, absorption ≥45dB, 0.02° sampling accuracy) to guarantee the measurement accuracy.
| Specifications | |
| Application | Phased array measurement Phase & magnitude calibration Aperture field diagnosis | 
| AUT | mmWave phased array measurement mmWave antenna measurement | 
| Frequency | 7.5GHz ~ 50GHz (up to 7.5GHz ~ 100GHz) | 
| Function | Antenna pattern (magnitude, phase, EIRP, EIS, Directivity, Single element calibration & diagnosis | 
| Shielding | > 90dB | 
| QZ Reflections level | <-40dB | 
| Measurement distance | 1600mm | 
| Power toleration | 10kW/m2 | 
| AUT | |
| AUT space | ∅ 1000mm x 700mm | 
| Max. size | 700mm x 700mm x 400mm (L x W x H) | 
| Max. weight | 100kg | 
| Probe | |
| Quantity | 4 | 
| Sampling range | -90°~90° | 
| Sampling accuracy | 0.02° | 
| 10dB beamwidth | ≤60° | 
| Cross-polarization ratio | ≤20dB (Main direction±15°) | 
| Absorber | |
| Material | EPP; High power tolerable honeycomb (optional) | 
| Absorption | ≥45dB (7.5GHz ~ 50GHz) | 
| Turntable | |
| Rotating accuracy | 0.01° | 
| X/Y adjusting range | ±50mm | 
| X.Y adjusting accuracy | ±0.01mm | 
| Theta adjusting range | 1° | 
| Theta adjusting accuracy | ±0.01° | 
| Size | |
| System | 400mm x 400mm x 3200mm (L x W x H) | 
| Door | 1000mm x 2000mm (W x H) | 