  • IEC/EN 61000-4-6
  • 110W, 10kHz - 400MHz amplifier
  • 4kHz - 1 GHz signal generator
  • Multiple monitoring options
  • 5.7" TFT color display
  • Remote control software & report generator
  • Optically decoupled remote control
  • Whisper remote

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The Teseq NSG 4070C-110 Test System for Conducted and Radiated Immunity is a 110W, 10kHz - 400MHz / 4kHz - 1GHz immunity testing device with a built in RF signal generator and power meter. Teseq NSG4070C models specialize in accompanying both conformity and development testing in compliance with IEC / EN 61000-4-6 and other automotive BCI standards like Namur. A modular setup allows for a versatility in application, and use of either internal or external amplifiers, with power amplifier modules varying in energy and frequency depending on the use. Data transfer is achieved by inserting a simple USB stick into the front panel.

RF
Frequency range4 kHz – 1 GHz
Resolution1 Hz
Reference frequency10 MHz
RF Level
Level range-60 dBm to +10 dBm
Resolution0.1 dB
Amplitude modulation
Modulation depth0 – 100%
Modulation frequency range1 Hz – 50 kHz
Frequency resolution1 Hz
Pulse modulation
Rise / fall time (10% / 90%)< 1 μs
Modulation frequency range0.1 Hz – 1 MHz
Frequency resolution0.01 Hz
Duty cycle0.1% to 100%
External modulation
Delay time< 1 μs / 180°
Periodmin. 20 μs
Pulse widthmin. 10 μs
Power Meter
Frequency range4 kHz to 1 GHz
Linear measurement range
channel 1-35 dBm to +27 dBm (NSG 4070C-60:-40 dBm to +27 dBm)
channel 2,3-45 dBm to +20 dBm
Max. input/no damageNoise level>5 dB below the measurement range
channel 1-3+28 dBm
Input return loss>20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
ConnectorBNC socket, 50 Ω
Accuracy 10 to 30°C
Power Amplifier
Nominal output power45 Watts
Frequency range9 kHz to 1 GHz
Input impedance50 Ω
Output impedance50 Ω
Input return lossmin. 10 dB
Output return lossnominal min. 9.5 dB, 0 dB without damage
Gainmin. 50 dB
Gain flatnessmax. +/- 3 dB
Saturated output power< 400 MHz 46.5 dBm
> 400 MHz 45.4 dBm
Linear output power Max. input power without damage max. +10 dBm< 400 MHz 45.4 dBm
> 400 MHz 43 dBm
Harmonic distortion at linear output powertyp. < -20 dBc