Coupling Networks for Burst + Surge

Quick Links

Information

Viewed products

Schloder CWG 1528 Four Unshielded Unsymmetrical Interconnection Lines View larger

Schloder CWG 1528 Four Unshielded Unsymmetrical Interconnection Lines

New

  • 4 lines 6A, 250 VAC
  • For surge test
    • line-to-line and line-to-ground coupling
  • RS 232

More details

Request Quote/More Info

PDF Downloads

Data Sheet

Schloder CWG 1528 Coupling Network Surge

PDF Downloads (61.12k)

Test Equipment Description

Schloder CWG 1528 Four Unshielded Unsymmetrical Interconnection Lines

The coupling network can be used to carry out EMC tests to the standards IEC 61000-4-5 (surge). The interference pulses of the surge generator are coupled to the interconnection lines of the tested unit. The coupling paths (line to line or line to earth) can be selected by using the coupling switches. The coupling network can be operated via an RS 232 interface with a personal computer – together with the surge generator CWG 1500 / CWG 500. So the selection of the coupling paths can be automated.

Technical Data
Nominal voltage ACmax. 240 V / 50 Hz
Nominal voltage DCmax. 120 V
Nominal /max. current4 x 6 A at 40° C ambient temperature
Decoupling inductance4 x 20 mH / 6 A (Serial choke)
Coupling capacity0,5 µF and 40 ohm
Max. surge pulse1,2/50 µs 4400 V
High voltage surge inputFischer high voltage jack D105A039
EUT feedinglaboratory-banana-jacks
EUT connectionlaboratory-banana-jacks
Remoteserial, RS 232
Power supply electronic control systemIEC-plug 230 V / 50 Hz / 1 A on rear side
Additional earth connection jackson front and rear side
Temperature environment0 - 40 °C
Rel. humidity0 – 60%
Cabinet19" housing, 3 HE
Weightapp. 14 kg