Viewed products
2 Lines 1 A For Surge Test Lines (D1...
One Used Haefely AXOS5 System...
New
Warning: Last items in stock!
Availability date:
With the coupling network CWG 1525 EMC-tests (immunity) on electrical equipment can be performed. Basic for these tests is the standard IEC 61000-4-5 (surge test for unshielded symmetrical interconnection lines).
The interference pulses of the Surge-Generator CWG 1500 are superposed to the interconnection lines of the EUT. Using the coupling switch the coupling paths can be switched on and off.
Technical data | |
Nominal Voltage AC | max. 50 V AC/DC |
Nominal Current IN | 2 x 1 A at TU = 40°Celsius |
Decoupling | 2 x 20 mH, current compensated choke |
Coupling Resistor | 2 x 80 ohm |
Coupling Device (CD) | Gas arrestors |
Coupling | Lines (D1 + D2) to ground |
Maximum Pulse Voltage 1,2/50 µs | 4.400 Volt |
High Voltage (HV) Input | Fischer HV-jack D105A039 |
Input Coupling Network | Laboratory jacks |
Output Coupling Network | Laboratory jacks |
Input Electronic Supply | IEC-plug, 230 V / 0,5 A on the rear |
Ground Connector Additional via Jack | on the front and rear |
Operation Temperature | 0 up to 40° Celsius |
Housing (H x W x D) | 150 x 225 x 360 mm (3HE; 42TE) |
Weight, approx. | 4,8 kg |