Coupling Networks for Burst + Surge

Quick Links

Information

Viewed products

Schloder CWG 1525 Two Unshielded Symmetrical Interconnection Lines View larger

Schloder CWG 1525 Two Unshielded Symmetrical Interconnection Lines

New

  • 2 Lines 1 A
  • For Surge Test Lines (D1 + D2) to Ground Coupling

More details

Request Quote/More Info

PDF Downloads

Data Sheet

Schloder CWG 1525 Coupling Network Surge

PDF Downloads (70.04k)

Test Equipment Description

Schloder CWG 1525 Two Unshielded Symmetrical Interconnection Lines

With the coupling network CWG 1525 EMC-tests (immunity) on electrical equipment can be performed. Basic for these tests is the standard IEC 61000-4-5 (surge test for unshielded symmetrical interconnection lines).

The interference pulses of the Surge-Generator CWG 1500 are superposed to the interconnection lines of the EUT. Using the coupling switch the coupling paths can be switched on and off.

Technical data
Nominal Voltage ACmax. 50 V AC/DC
Nominal Current IN2 x 1 A at TU = 40°Celsius
Decoupling2 x 20 mH, current compensated choke
Coupling Resistor2 x 80 ohm
Coupling Device (CD)Gas arrestors
CouplingLines (D1 + D2) to ground
Maximum Pulse Voltage 1,2/50 µs4.400 Volt
High Voltage (HV) InputFischer HV-jack D105A039
Input Coupling NetworkLaboratory jacks
Output Coupling NetworkLaboratory jacks
Input Electronic SupplyIEC-plug, 230 V / 0,5 A on the rear
Ground Connector Additional via Jackon the front and rear
Operation Temperature0 up to 40° Celsius
Housing (H x W x D)150 x 225 x 360 mm (3HE; 42TE)
Weight, approx.4,8 kg

8 other products in the same category: