The ECCSS LISN 2 was developed following the "European Cooperation for Space Standardisation". The ECSS LISN 2 is used for DC mains lines. The red wing terminal must be connected to the positive voltage, the black terminal to the negative. The impedance characteristic of each path is basically realized by an inductor in parallel with the 50 Ohm resistor: 2 µH || 50 Ω.
The device under test has to be connected to the terminals at the front panel. The supply voltage has to be connected at the back panel.
The device under test may drain a continuous current of 10 A and for a short period of time it may even drain more than 15 A.
Principle Circuit Diagram of the ECSS LISN 2
Attention:
The built in capacitors are electrolytic so the correct polarity is a MUST!
The impedance between plus /minus EuT-Terminal and the metal enclosure of the LISN
(Calibration Adapter KA ECSS required)
Specifications | |
Frequency Range | 10 Hz – 150 MHz |
Max. cont. current | 10 A |
Max. current (limited time) | 15 A |
Max voltage (DC) | 200 V |
Impedance | (2 µH) || 50 Ω (+/- 10%) |
DC-Resistance mains-EuT | 100 mΩ |
EuT connectors | Screw terminal M7x0.75 not unscrewable with 4mm jacks |
Housing dimensions (WxHxD) | 160x165x210 mm |
Weight | 2.7 kg |