Viewed products
Max.withstand current: 1A Signal...
Max. current: 1A Data rate up to...
New
Industries
Warning: Last items in stock!
Availability date:
Design and performance of coupling/decoupling network is clearly specified in IEC/EN 61000-4-6. Cable type and transferred signals used for each type of coupling/decoupling network are also specified in the standard. CDN ST81 is designed for four-pair 8-line shielded balanced line as per IEC/EN 61000-4-6.
As per
| Technical Parameters | |
| Model | CDN ST8 |
| Standard | IEC/EN 61000-4-6 |
| Frequency range | 150KHz-230MHz |
| Max. AC voltage (line to ground) | 100V |
| Max. DC voltage (line to ground) | 150V |
| Max. current | 1A |
| RF input port (BNC) | <20V |
| EUT port type | RJ45 |
| AE port type | RJ45 |
| Common mode impedance (EUT) | |
| 26MHz-80MHz | 150Ω +60Ω /-45Ω |
| Differential voltage factor(RF input-EUT | |
| 150KHz-26MHz | 150Ω±20Ω |
| 26MHz-80MHz | 150Ω +60Ω /-45Ω |
| Common mode impedance (EUT) | |
| 150KHz-80MHz | 9.5dB±1dB |
| 80MHz-230MHz | 9.5dB±2dB |
| Common mode interference (RF port / AE) | |
| 150 kHz | >60 dB |
| 1.5 MHz | >60 dB |
| 30 MHz | >60dB |
| 80 MHz | >50 dB |
| 230 MHz | >40 dB |
| Optional Accessories | |
| CAL 100F | 150Ω to 50Ω calibration device |
| CAL 150F | 150Ω calibration device |
| CDN ADP SRJ45 | Calibration adapter |
| General Data | |
| Weight | 2.0kg |
| Size | Long ×wide ×high 21×13×10cm |
| Case material | Aluminum |
| Temperature | 5°C - 40°C (operating condition) |
| Humidity | 20% - 80% (operating condition) |
| Package | Carton |