Surge Data Lines Surge CDN's

Quick Links

Information

Viewed products

Haefely DEC 6 Decoupling Network for Symmetrical Data and Control Lines View larger

Haefely DEC 6 Decoupling Network for Symmetrical Data and Control Lines

New

  • Decoupling resistors 200 Ohm
  • 10/700us telecom impulses and combination wave 1.2/50us - 8/20us impulses
  • 100kHz ring wave impulses
  • Breakdown avalanche diodes and gas arrestors as protection elements
  • Up to 4 wires can be tested
  • Signal Bandwidth up to some 10MHz

More details

In Stock

Request Quote/More Info

Specifications

CouplingDecoupling elements Resistors 200 Ohm
DUT currentCurrent on EUT lines max. 0.1A
Pulse amplitudemax. 6.6kV
Test VoltageVoltage on EUT lines max. 72V DC or 50V AC,RMS (with gas arrestors as protection elements) max. 144V DC or 100V AC,RMS (with ABDs as protection elements)
Pulse Shape10/700us -5/320us 1.2/50us - 8/20us 100kHz ring wave
Dimensions30 x 20 x 16 cm (w x h x d)
Weightapprox. 2 kg net

Test Equipment Description

Haefely DEC 6 Decoupling Network Description:

The Haefely DEC 6 is used for decoupling auxiliary equipment from an EUT tested with 10/700us impulses up to 6.6kV peak. It is used to decouple unshielded symmetrical data and signal lines according standard ITU K.44. Up to 4 wires can be tested simultaneously.
To obtain maximum flexibility only decoupling and protection elements are included in the DEC 6. Coupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup.
Manual coupling selection of the protection elements for best protection of the auxiliary equipment.
Default protection elements are gas arrestors and breakdown avalanche diodes (ABDs). With such elements the capacitive load to the EUT lines is small. The decoupling elements can be selected easily. It is also possible to test without any protection elements.
The DEC 6 can be used together with the coupling networks PCD 120, PCD 122 and PCD 800. These provide all the coupling elements as required to perform IEC, ANSI, FCC and EN testing.

Haefely DEC 6 Decoupling Network Applications:

  • Unshielded symmetrical data and signal lines
  • Telecommunication equipment
  • Other international requirements for surge testing symmetrical data
  • and control lines such as TIA 968 A (FCC part 68)
Specifically designed to meet and exceed the requirements of:
  • EC / EN 61000-4-5 Edition 1 Figure 12 (*)
  • IEC / EN 61000-4-5 Edition 2 Figure 14 (*)
  • IEC / EN 61000-4-12 Edition 2 Figure 12 (*)
  • ITUK.44: 2003 Figures A.5-1, A.6.1-1 to A.6.1-5

Associated EMC Test Equipment

9 other products in the same category: