1 Line CDN

Quick Links

Information

Viewed products

EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC, 16A, 150kHz - 230MHz - EMC Test Equipment View larger

EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC

New

  • AE: 4mm safety lab connector
  • EUT: 4mm safety lab connector
  • AC: max. 250 Volts, 16/32/50/75/100 Amps
  • DC: max. 1,000 Volts, 16/32/50/75/100 Amps
  • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)

More details

Typically In Stock

Request Quote/More Info

Specifications

Voltage Rating250 V AC / 1,000 V DC
Frequency Range150 kHz to 230 MHz
Standards MetIEC / EN 61000-4-6
Mains & EUT Connections4mm safety lab connector
Current Rating16 Amps (Max)
Application/Test TypeCoupling/decoupling networks for Conducted immunity, mains AC power supply lines
RF Input Voltage30 V (Max)

Test Equipment Description

The EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC is an M-type coupling/decoupling network for mains AC power supply lines.

Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines. 

For testing conducted RF immunity according to IEC 61000-4-6 and IEC / EN 60945 different types of CDN are required, depending on cable. Specific CDNs are also used for emission measurements according to CISPR 15 and EN 55015. 

EM Test (Lüthi) offers a wide selection of appropriate coupling / decoupling networks, and current probes and the associated accessories for standard-compliant calibration.

EM Test (Lüthi) M1 CDN Specifications:

  • AE: 4mm safety lab connector
  • EUT: 4mm safety lab connector
  • AC: max. 250 Volts, 16/32/50/75/100 Amps
  • DC: max. 1,000 Volts, 16/32/50/75/100 Amps
  • Frequency 150 kHz - 230 MHz (up to 80 MHz on 50 Amp models)

EM Test (Lüthi) M1 CDN Specifications:

  • CDN M1: CDN for Earth conductor 250V AC / 1,000V DC, 16A, 150kHz - 230MHz
  • CDN M1-32A: CDN for Earth conductor 250V AC / 1,000V DC, 32A, 150kHz - 230MHz
  • CDN M1-32A/1000V: CDN for Earth conductor 1,000V AC / 1,000V DC, 32A, 150kHz - 80MHz
  • CDN M1-50A: CDN for Earth conductor 250V AC / 750V DC, 50A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M1-75A: CDN for Earth conductor 250V AC / 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M1-100A: CDN for Earth conductor 250V AC / 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port

Associated EMC Test Equipment