Isolate your DUT (device under test) and provide a stable impedance during your conducted emission testing. Use a line impedance stabilization network (LISN) for pre-compliance evaluation or certification testing for IEC/EN, Mil-STD and other international compliance standards. The EMC Shop is an ISO 17025 accredited company, stocking 1ph and 3ph Line Impedance Stabilization Networks (LISN's) for immediate shipment.

 

Get Application Support, Pricing, Lead Time and More: Contact Form

Line Impedance Stabilization Networks (LISN's) There are 73 products.

Subcategories

  • Impedance Stabilization Networks (ISN's)

    Impedance stabilization networks (ISN's) are similar to LISN's but used for conducted emissions measurements on signal and data lines. They differ from LISN's in that they can perform Comon-Mode impedance measurements. CISPR 22 and CISPR 32 are common standards requiring the use of an ISN.

    ISN's are referred to as an asymmetric artificial network (AAN) in CISPR 16-1-2.

  • MIL-STD-461 LISN's

    The EMC Shop specializes in MIL-STD-461 and other military compliance testing. Stocking sets of LISN's rated for up to 200 amps, customers can rent or buy line impedance stabilization networks for MIL-STD-461 online, and receive the equipment to begin testing immediately.

  • CISPR 16 LISN's

    The EMC Shop specializes in immunity and emissions compliance testing, evlaution and consulting for product developers, electrical engineers and other R&D work. While LISN's aren't essential for precompliance testing and product debugging, utilizing them to ensure consistent impedance throughout will help ensure reliable and consistent test data. Rent, buy or lease CISPR 16 LISN's - Line Impedance Stabilization Networks. 

  • CISPR 25 / ISO 7637 Automotive LISN's

    The EMC Shop specializes in automotive emissions compliance testing and evaluation. Rent, buy or lease CISPR 25 / ISO 7637 Automotive  - Line Impedance Stabilization Networks. 

    CISPR 25 / ISO 7637 Automotive LISN Test Setup

    CISPR 25 / ISO 7637 Automotive LISN Test Setup

  • RTCA / DO-160 LISN's

    The EMC Shop specializes in emissions compliance testing and evaluation. Rent, buy or lease RTCA / DO-160 LISN's - Line Impedance Stabilization Networks. 

  • ANSI C63.4 LISN's

    The EMC Shop specializes in emissions compliance testing and evaluation. Rent, buy or lease ANSI C63.4 LISN's - Line Impedance Stabilization Networks. 

  • FCC Part 15 LISN's

    The EMC Shop specializes in emissions compliance testing and evaluation. Rent, buy or lease FCC Part 15 LISN's - Line Impedance Stabilization Networks.

  • Three Phase LISN 's

     

    EMC/EMI Testing Services          Radiated Immunity & Susceptibility           Antenna Testing            Emissions Testing

     

    The EMC Shop stocks most test equipment needed for compliance testing. Rent, buy or lease three phase LISN's, line impedance stabilization networks per CISPR 16.  Electromagnetic compatibility (EMC) test equipment is used to evaluate the electrical conducted or wireless performance and integrity of any product, from automobiles to furniture.

     

    Get Application Support, Pricing, Lead Time and More: Contact Form

     



per page
Showing 37 - 48 of 73 items
    • 150 kHz – 230 MHz Frequency Range
    • ISN acc. CISPR 22 Ed.5.5:2006, Annex D, D9 for coaxial lines
    • Can be used to measure the conducted voltage emissions of telecommunication and data processing equipment
    • It is designed to measure coaxial line. It is based on IEC/CISPR 22 and the related national standards
    • Provide sufficient decoupling from the equipment under test (EuT) to the auxiliary equipment (AE)
    In Stock
    Request Quote/More Info
    • 150 kHz – 230 MHz Frequency Range
    • ISN acc. CISPR 22 Ed.5.5:2006, Annex D, D9 for coaxial lines
    • Can be used to measure the conducted voltage emissions of telecommunication and data processing equipment
    • It is designed to measure coaxial line. It is based on IEC/CISPR 22 and the related national standards
    • Provide sufficient decoupling from the equipment under test (EuT) to the auxiliary equipment (AE)
    In Stock
    Request Quote/More Info
    • It consists of two identical channels for the lines "A" and "B".
    • It is constructed with air core inductors, in order to avoid intermodulation interference.
    • Frequency range of 9 kHz to 1 GHz can be measured.
    • Lower-frequency interference that may cause damage to the measuring receiver input shall be mitigated by additional high-pass filters.
    In Stock
    Request Quote/More Info
    • 10 Hz – 150 MHz Frequency Range
    • 10 A  Max. cont. current
    • 15 A  Max. current (limited time)
    • European Cooperation for Space Standardisation
    • Used for DC mains lines
    In Stock
    Request Quote/More Info
    • 10 Hz – 100 MHz Nominal Frequency Range
    • 10 Hz – 150MHz Useable Frequency Range
    • 75 A Max. cont. current
    • 100 A Max. current (limited time)
    • European Cooperation for Space Standardisation
    • Used for DC mains lines
    In Stock
    Request Quote/More Info
    • 10 Hz – 150 MHz Frequency Range
    • 10 A Max. cont. current
    • 15 A Max. current (limited time)
    • European Cooperation for Space Standardisation
    • Used for DC mains lines
    In Stock
    Request Quote/More Info
    • 10 Hz – 150 MHz Frequency Range
    • 10 A Max. cont. current
    • 15 A Max. current (limited time)
    • European Cooperation for Space Standardisation
    • Used for DC mains lines
    In Stock
    Request Quote/More Info
    • V-LISN
    • (9) 150 kHz - 100 MHz
    • (50 µH + 5Ω) || 50Ω
    • 800 A (1000 A)
    • 1000 VCD / 250 VAC (50/60 Hz)
    • Single Path
    • Mil. Std. 461E
    In Stock
    Request Quote/More Info
    • V-LISN
    • (9) 150 kHz - 100 MHz
    • (50 µH + 5 Ω) || 50 Ω
    • 70 (100) A
    • 50 Hz AC 250 V
    • Single Path
    • Mil. Std. 461/462
    In Stock
    Request Quote/More Info
    • V-LISN
    • (9) 150 kHz - 30 MHz
    • 50 µH || 50 Ohm
    • 4 x 400 (500) A
    • Wing Terminals
    • Low Voltage Drop
    • Cooling Fans
    In Stock
    Request Quote/More Info
    • V-LISN, 9 kHz - 30 MHz
    • 50 µH + 5 Ohm || 50 Ohm
    • 2 x 16 A Schuko socket
    • Artificial Hand
    In Stock
    Request Quote/More Info
    • PV-LISN for the DC side of grid connected power converters GCPC.
    • 1500 V
    • 200 A
    • Common Mode Impedance = 150 Ohm
    • Differential Mode Impedance = 150 Ohm
    • Air Coils 280 Microhenry
    In Stock
    Request Quote/More Info