Coupling Decoupling Networks (CDN's)

Quick Links

Information

Coupling Decoupling Networks (CDN's)

 

The EMC Shop stocks coupling decoupling networks (CDN's) for most power and data line configurations. CDN's are quintessential for performing EMC testing. In short, conducted immunity coupling networks ensure electrical transients are sent down the path of the line to the EUT. Decoupling that signal from entering the rest of the network is done in different ways. In radiated immunity, you are coupling wireless signals over the air through the antenna. It may be appropriate to use a decoupling clamp on lines as they exit the test chamber.



Get Application Support, Pricing, Lead Time and More: Contact Form



Coupling/Decoupling networks are built in to most current generators for single phase power EUT. Coupling networks are typically easy to set up for conducted immunity (surge, EFT, PQF). RF conduted immunity requires an assortment of couplers and without proper setup, are easy to blow up.

Type's of Coupling Decoupling Networks

  • CDN's for Surge/EFT Immunity: Power Lines and Data Lines
  • RF CDN's for Conducted Immunity: Power Lines and Data Lines: Used for just decoupling as well
  • EM Clamps: Inject and decouple RF disturbances
  • Absorbing Clamps: Just for decoupling RF disturbances on cables (Needed for BCI Testing)
  • Bulk Current Injection Probes: Used for just coupling RF noise

RF Conducted Immunity CDN Test Setup

Coupling Decoupling Networks (CDN's) - The EMC Shop

 

Coupling/decoupling networks for RF conducted immunity have a port top-side where your inject the RF signal, an EUT side where the RF disturbances are directed to power or data lines. The decoupling path exit the AE Side and is generally safe from disturbances.

Coupling Decoupling Networks (CDN's) There are 51 products.

Subcategories

  • RF Power Line CDN's

    The EMC Shop stocks power line coupling decoupling networks for RF conducted immunity testing. The distubance signals are coupled to each conductor in the supply lines according to EN IEC 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. CDNs are available for power supplies from 1 to 5 conductors.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    RF Power Line CDN's

    • M1 for one line
    • M2 for two lines
    • M2/3 switchable for two or three lines
    • M3 for three lines
    • M4 for lines and
    • M5 for five lines "-10 types" for frequency range 10 kHz to 80 MHz
    • "-3L and -3LN types" for connections without PE "-750V, -760V
    • -1000V types" for higher EUT voltages

  • RF Data Line CDN's

     

    The EMC Shop stocks data line coupling decoupling networks for RF conducted immunity testing. Order RF data line CDN's today. The EMC Shop specializes in RF conducted immunity testing to EN/IEC 61000-4-6 and other test standards. Calibrated S-Type coupling decoupling networks are in stock and avaialable to ship with turnkey RF test generators and systems.

     

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • EM Injection Clamps

    The EMC Shop stocks EM injection clamps for RF conducted immunity testing, typically for IEC 61000-4-6. Rent or buy individual EM injection clamps or order a complete turn key system. Calibration adapters are also available upon request.



    Comparison Tool: Popular EM Injection Clamps



    Get Application Support, Pricing, Lead Time and More: Contact Form



    EM Injection clamps are used to inject a known level of RF signal onto the cabling of EUT at a test frequency and verify the EUT still performs accordingly. 



    Standards Using EM Injection Clamps

    • IEC 61000-4-6: international standard for most commercial electornics
    • IEC 60533: EMC for ships with a metallic hull
    • CISPR 24: Immunity requirements for information technology equipment (ITE)
    • IEC 60601-1-2: EMC requirements for medical equipment
    • IEC 61326-1: Immuniy and emissions for electrical equipment

  • EM Absorbing Clamps

    Capacitive coupling/absorbing clamps are used for measuring interference signals on power supply cables. Decoupling clamps and ferrite tube are available for a variety of different EMC applications.

  • Surge/EFT/PQF 3-Phase CDN's

    For large commercial products requiring three phase power at 240V, 480V or 600V. An additional CDN will required with the transient generators to complete IEC 61000-4-4, IEC 61000-4-5ANSI C62.45 and other conducted immunity testing. The EMC Shop stocks 3 Phase coupling/decoupling networks for rental or purchase.

    Get Application Support, Pricing, Lead Time and More: Contact Form


    Three Phase CDN Diagram per IEC 61000-4-5

    Coupling/Decoupling Network Diagram for 3-Phase EUT per IEC 61000-4-5

    Three Phase CDN Coupler Applications

    EN/IEC 61000-4-5

    EN/IEC 61000-4-4

    ANSI (IEEE) C62.45

    EN/IEC 61000-4-11

    EN/IEC 61000-4-29

     

  • Surge Data Lines Surge CDN's

    The EMC Shop is an ISO 17025 accredited company. Contact us to rent of buy Data Lines Surge CDN's .

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Data Lines Surge CDN's Standards:

    EN/IEC 61000-4-5

    EN/IEC 61000-4-4

    ANSI (IEEE) C62.45

    EN/IEC 61000-4-11

    EN/IEC 61000-4-29

     

  • CDN Calibration Accessories

    CDN Calibration accessories for compliance standards testing. The EMC shop carries a variety of CDN calibration accessories that are in stock and ready to ship!

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 3 Phase CDN's for EFT/Burst

    External coupling/decoupling networks are required for 3 Phase AC power line testing against electrical fast transients (burst). The EMC Shop stocks a variety of 3 Phase EFT/Burst manual CDN's that are immediately available to rent or buy.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Common Applications

    Teseq NSG 3040-EFT

    Teseq NSG 3060

    Burst/EFT Generators

  • EFT Coupling Clamps

    Capacitive coupling clamps are primarily used to inject fast transient and burst interference pulses into signal and data cables, i.e. into any type of connection to peripheral equipment. The IEC standard 61000-4-4 Ed. 3 also allows the capacitive coupling method to be used for pulse injection into ac and dc power lines when no appropriate decoupling network is available. The coupling capacitance (typically 100pF) between the coupling clamp and the cable inserted depends on the cable type, the diameter and other factors like screening, etc.



    Get Application Support, Pricing, Lead Time and More: Contact Form



    EFT Coupling Clamp Tests

     

per page
Showing 25 - 36 of 51 items
    • 0.15 kHz - 230 MHz
    • 4 mm Safety Banana Sockets
    • 16 A Max. Current rating
    • 250 VAC 400 VDC Input Voltage EUT
    • For conducted common mode immunity testing according to IEC 61000-4-6
    • Complies to IEC 61000-4-6 Annex D2
    • Suitable for immunity testing on unscreened a.c. and d.c. power supply lines (mains lines)
    Typically In Stock
    Request Quote/More Info
    • Decoupling pulse voltage up to 20kV
    • Decoupling impulse current 10kA
    • Decoupling lightening voltage wave of long tail
    • Decoupling pulse width up to 300μs
    • Decoupling lightening surge waveform: voltage wave 4/300μs
    • Voltage wave 10/200μs
    • Combination wave 1.2/50μs,8/20μs
    • Combination wave 10/700μs,5/320μs

    Standard

    • IEC 61000-4-5
    • IEC 61010-1
    • GB/T 3483
    • EN 61000-4-5
    In Stock
    Request Quote/More Info
    • Electromagnetic relay protection if current is more than rated value
    • Scheduling setting and save test time

    Standard

    • IEC 61000-4-5
    • IEC 61000-4-4
    • GB/T 17626.5
    • GB/T 17626.4
    In Stock
    Request Quote/More Info
    • For use with one, two, three, or four unscreened balanced pairs
    • Refers schematic circuit example in CISPR 22/32 Figure D.3/G.3
    • Intended for connection to cable category 3 and 5
    • 1000BaseT and PoE application
    • Changeable pin-arrangements with RJ11 and RJ45

    Purchase Teseq ISN T8

    In Stock
    Request Quote/More Info
    • Inquire for specific models available
    • CDN T-Type
    • Terminal clamp (T2, T4); RJ45 female (T8) Connectors
    • Coupling / Decoupling of disturbing signal to unscreened balanced interconnection lines
    • 10 kHz – 80 MHz / 230 MHz
    Typically In Stock
    Request Quote/More Info
    • Inquire for specific models available
    • CDN RJ-Type
    • Coupling / Decoupling of disturbing signal to unscreened balanced interconnection lines
    • 150 kHz – 80 MHz / 230 MHz
    Typically In Stock
    Request Quote/More Info
    • Inquire for specific models available
    • CDN AF-Type
    • Coupling / Decoupling of disturbing signal to unscreened unsymmetrical nonbalanced interconnection lines
    • 150 kHz – 80 MHz / 230 MHz
    Typically In Stock
    Request Quote/More Info
  • Quick view
    $99.00 Monthly
    • Monthly Rental Ships Immediately
    • 150 kHz - 230 MHz
    • Suitable for testing one unscreened balanced pair for IEC/EN 61000-4-6
    • Ethernet RJ45 Adapters Supplied
    $99.00
    In Stock
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • Testing for 75 Ohm Coaxial Cables
    • Includes calibration adapters
    • Turnkey test systems available
    • Rent the Teseq CDN S751AS
    $1,245.00
    Typically In Stock
    Request Quote/More Info
  • Quick view
    $1,810.00 NIST Traceable
    • Coupling networks designed for IEC/EN 61000-4-6, CISPR 22, IES 60601-1-2 and more.
    • S-type CDN for screened data and telecom lines, ethernet, and HDMI (see USB CDN's)
    • 50 Ohm/75 Ohm Coaxial Cables
    • High speed HDMI with HDCP, HEC (Ethernet), ARC and DSC
    • XLR-Audio, pin 3 to ground
    $1,810.00
    Typical Lead time: 4 - 6 Weeks
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • RS-232, D-sub, 9 Pin connector for screened data and telecom lines,
    • Frequency Range: 150 kHz - 230 MHz
    • Power Rating: 150 V Line to Ground (AC + DC)
    • Current Max: 250 mA
    • Injection Method: 50 Ohms, BNC <20 Volts
    $1,190.00
    Typically In Stock
    Request Quote/More Info
    • AE: 4mm safety lab connector
    • EUT: 4mm safety lab connector
    • AC: max. 250 Volts, 16/32/50/75/100 Amps
    • DC: max. 1,000 Volts, 16/32/50/75/100 Amps
    • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)
    Typically In Stock
    Request Quote/More Info
Showing 25 - 36 of 51 items