  • Broad High Frequency Response: 1 MHz - 400 MHz
  • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
  • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
  • Split Type Clamp-on Design
  • Current injection source as well as a sensitive monitoring probe.
  • Insertion Loss: 4 to 22 dB
  • Max Input Power: 100 Watts CS

More details

Typically In Stock

Request Quote/More Info

Specifications

Frequency Range1 MHz - 400 MHz
Application/Test TypeBulk injection testing for RF conducted immunity and emissions. (works as sensitive monitoring probe)
Insertion Loss4 to 22 dB
Input100 watts max power
ConnectorN-Type, Female
Aperture1.6"
VSWR5" Diameter
Weight4 Lbs

Test Equipment Description

**The AH Systems ICP-522 has been discontinued. Click the link below for the new version.**

AH Systems ICP-622 RF Current Injection Probe, 2 MHz - 500 MHz

The purpose of the test is to determine that RF signals in the range of 10 KHz to 400 MHz, when coupled onto conductors and cable bundles will not cause failure or degradation of their circuit performance. Bundles of wires will be tested with the injection current probes clamped around all wires. If primary power wires utilize the same connector as control and signal lines, they will be included in the test. Every primary power wire will be tested as a single circuit. If they are contained within a bundle, they will be separated and tested. Aircraft flight safety critical equipment will have their wires tested individually for compliance to DO-160.

The A.H. Systems' series of Injection Current Probes offer a wide operating frequency range of 10 kHz to 1000 MHz.  The geometry of the probes optimize coupling to the circuit under test.  Each probe comes with an N-type connector.

Typical specifications requiring the use of current injection probes are:

  • IEC 61000-4-6
  • Mil-Std 461
  • DO-160
  • EN-50081-1
  • IEC 801-6
  • TR-EOP-000063

AH Systems ICP-522 Features:

  • Broad High Frequency Response: 1 MHz - 400 MHz
  • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
  • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
  • Split Type Clamp-on Design
  • Current injection source as well as a sensitive monitoring probe.
  • Insertion Loss: 4 to 22 dB
  • Max Input Power: 100 Watts CS

Associated EMC Test Equipment