Quick Links

Information

EN/IEC 61000-4-6

 

EMC/EMI Testing Services         Radiated Immunity & Susceptibility        Antenna Testing            Emissions Testing

 

The EMC Shop rents this test equipment, allowing for preliminary testing and evaluation before attempting to certify the product. The IEC/EN 61000-4-6 test standard should be purchased, read and followed to develop a suitable test plan and effectively evaluate your product.

 

EN/IEC 61000-4-6 Testing

EN/IEC 61000-4-6 is the normative reference standard to test electronic products immunity to RF conducted injected interference. RF conducted interference is phenomena as simple as placing a wireless device on or near power cables or data lines that can couple wireless through the shielding of those lines and affect associated equipment. More complex situations include cable bundles in a car chassis that may cause the RF conducted affect and impact other lines, and travel to the electronics. RF conducted immunity test equipment will generate more than anticipated RF fields we would expect in the real world. Engineers exercise their equipment across the frequency band, typically 150 kHz to 80 or 230 MHz, to gauge how their product responds to the interference.

Injection Method Selection

EN/IEC 61000-4-6 Injection Method Selection Chart

EN/IEC 61000-4-6 Videos



 

EN/IEC 61000-4-6 Procedure

  • Identify Amount of Ports to EUT
  • Identify Coupling Methods
  • Generate Pass/Fail Criteria
  • Determine 61000-4-6 Test Levels
  • Calibrate System
  • Connect EUT and Test
  • Document Results
  • Troubleshoot Accordingly

EN/IEC 61000-4-6 There are 99 products.

Subcategories

per page
Showing 85 - 96 of 99 items
  • Request Quote/More Info
    • Broad High Frequency Response: 1 MHz - 400 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 22 dB
    • Max Input Power: 100 Watts CS
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Typically In Stock
    Request Quote/More Info
    • Frequency Range: 1 MHz - 1 GHz
    • Rugged Design
    • IEC 61000-4-6
    • Mil-STD 461D/E/F

    Typically In Stock
    Request Quote/More Info
    • For screened cables, 9 lines
    • AE: USB 3.0 (B) connectors
    • EUT: USB 3.0 (A) connectors
    • AC/DC: max. 100 V /1 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 6 - 8 Weeks
    Request Quote/More Info
    • For 1 screened coaxial line
    • AE/EUT: BNC, N-Type, SMA connectors 50 ohm (BNC & N-Type available for 75 Ohm)
    • AC/DC: max. 100 V/0.25 A
    • Frequency 150 kHz - 230 MHz
    In Stock
    Request Quote/More Info
    • For 4 screened lines
    • AE/EUT: BNC-connectors, USB (A/A) connectors, Sub-D9 connectors
    • AC/DC: max. 100-125 Volts / 1-1.5 Amps
    • Frequency: 150 kHz - 80 MHz (USB: 150 kHz - 230 MHz)
    Typical Lead Time 6 - 8 Weeks
    Request Quote/More Info
    • For 1 screened coaxial line
    • AE/EUT: BNC, N-Type, SMA connectors 50 ohm (BNC & N-Type available for 75 Ohm)
    • AC/DC: max. 100 V/0.25 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • Dual directional coupler
    • Wide frequency range
    • High power handling
    • Designed for EMC immunity applications
    • BCI and radiated immunity
    4-6 Weeks
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • M2 series for mains applications
    • Models with 4 mm banana sockets
    • Models with frequency range 10 kHz to 80 MHz, 150 kHz to 230 MHz or up to 300 MHz
    • Very efficient coupling also for 100 Amps CDNs
    In Stock
    Request Quote/More Info
    • Meets civilian and military standards (e.g. IEC/EN 61000-4-3; IEC/EN 61000-4-6; ISO 11452-4; MIL-STD-461G; etc.)
    • Suitable for conducted, radiated and automotive immunity tests
    • 9 kHz to 230 MHz frequency range
    • 10 W power output (15 W from 150 kHz to 80 MHz)
    • 40 dB power gain • Class A linear solid-state amplifier
    • 50 Ω input/output impedance • Analog meter and LED indicators
    • Fan air cooling
    In Stock
    Request Quote/More Info
    • RF Power Amplifier ACS-230-25W/50W/100W
    • For IEC 61000-4-6 Testing
    • Frequency range of 150 kHz to 250 MHz
    • Wide Selection of CDNs
    • Software Automation
    • CISPR 16 compliant CDNs
    • Attenuators
    Typically In Stock
    Request Quote/More Info
Showing 85 - 96 of 99 items