Quick Links

Information

EN/IEC 61000-4-6

 

EMC/EMI Testing Services         Radiated Immunity & Susceptibility        Antenna Testing            Emissions Testing

 

The EMC Shop rents this test equipment, allowing for preliminary testing and evaluation before attempting to certify the product. The IEC/EN 61000-4-6 test standard should be purchased, read and followed to develop a suitable test plan and effectively evaluate your product.

 

EN/IEC 61000-4-6 Testing

EN/IEC 61000-4-6 is the normative reference standard to test electronic products immunity to RF conducted injected interference. RF conducted interference is phenomena as simple as placing a wireless device on or near power cables or data lines that can couple wireless through the shielding of those lines and affect associated equipment. More complex situations include cable bundles in a car chassis that may cause the RF conducted affect and impact other lines, and travel to the electronics. RF conducted immunity test equipment will generate more than anticipated RF fields we would expect in the real world. Engineers exercise their equipment across the frequency band, typically 150 kHz to 80 or 230 MHz, to gauge how their product responds to the interference.

Injection Method Selection

EN/IEC 61000-4-6 Injection Method Selection Chart

EN/IEC 61000-4-6 Videos



 

EN/IEC 61000-4-6 Procedure

  • Identify Amount of Ports to EUT
  • Identify Coupling Methods
  • Generate Pass/Fail Criteria
  • Determine 61000-4-6 Test Levels
  • Calibrate System
  • Connect EUT and Test
  • Document Results
  • Troubleshoot Accordingly

EN/IEC 61000-4-6 There are 99 products.

Subcategories

per page
Showing 61 - 72 of 99 items
    • 9kHz to 1GHz Signal Generator 
    • Amplitude modulation: 1Hz to 3kHz (0% to 95%)
    • Pulse modulation: 1Hz - 1kHz (10% to 90%)
    • Built-in amplifier, 100kHz to 300MHz 
    • Built-in current monitor, 9kHz to 1GHz  
    Typically In Stock
    Request Quote/More Info
    • Wide frequency range 10 kHz - 400 MHz
    • High power handling (up to 1 kW)
    • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements
    • Meets IEC/EN 61000-4-6
    • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 1 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Typically In Stock
    Request Quote/More Info
    • Model CI00250A (75 Watt amplifier, 10 kHz – 250 MHz)
    • Model CI00400A (100 Watt amplifier, 10 kHz – 400 MHz)
    • Model CI00401A (150 Watt amplifier, 100 kHz – 400 MHz) 
    • EN/IEC 61000-4-6 Testing Solution
    In Stock
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • Testing for 75 Ohm Coaxial Cables
    • Includes calibration adapters
    • Turnkey test systems available
    • Rent the Teseq CDN S751AS
    $1,245.00
    Typically In Stock
    Request Quote/More Info
  • Quick view
    $1,810.00 NIST Traceable
    • Coupling networks designed for IEC/EN 61000-4-6, CISPR 22, IES 60601-1-2 and more.
    • S-type CDN for screened data and telecom lines, ethernet, and HDMI (see USB CDN's)
    • 50 Ohm/75 Ohm Coaxial Cables
    • High speed HDMI with HDCP, HEC (Ethernet), ARC and DSC
    • XLR-Audio, pin 3 to ground
    $1,810.00
    Typical Lead time: 4 - 6 Weeks
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • RS-232, D-sub, 9 Pin connector for screened data and telecom lines,
    • Frequency Range: 150 kHz - 230 MHz
    • Power Rating: 150 V Line to Ground (AC + DC)
    • Current Max: 250 mA
    • Injection Method: 50 Ohms, BNC <20 Volts
    $1,190.00
    Typically In Stock
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 80 W, 150 kHz to 230 MHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
    • Integrated signal generator 9 kHz to 1 GHz
    • 3 power meter inputs 9 kHz to 1 GHz
    • Integrated power amplifier module for different applications
    • Multiple EUT monitoring options
    • Optional built-in amplifier up to 75 watts (150 kHz - 230 MHz)
    • Meet IEC 61000-4-6,  IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 
    • Meet Mil-STD 461 CS114
    In Stock
    Request Quote/More Info
    • For 4 AC supply lines (L1/L2/L3/PE or N)
    • AE: 4mm safety lab connectors
    • EUT: 4mm safety lab connectors
    • AC: max. 3 x 400 V/16 A
    • DC: max. 1,000 V/16 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • For 5 AC supply lines (L1/L2/L3/N/PE)
    • AE: 4mm safety lab connectors
    • EUT: 4mm safety lab connectors
    • AC: max. 3 x 750 Volts / 100 Amps
    • DC: max. 1,000 Volts /100 Amps
    • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • For 2 or 3 AC/DC supply lines (switchable)
    • AE: IEC 60320/C14 connector
    • EUT: 4mm safety lab connectors
    • AC/DC: max. 240 V/32 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
Showing 61 - 72 of 99 items