M Series

Quick Links

Information

Viewed products

Com-Power CDN-M250E 150 kHz - 230 MHz Unscreened Power Supply Line View larger

Com-Power CDN-M250E 150 kHz - 230 MHz Single line Plus Netural 50 Amp

New

  • 150 MHz to 230 MHz Frequency Range
  • Meets CISPR 16-1-2 and 61000-4-6 requirements
  • Current handling up to 50 Amps AC
  • Individual calibration
  • Three Year Warranty

More details

Request Quote/More Info

PDF Downloads

Specifications

Frequency range150 kHz to 230 MHz
Current Rating50 Amps (AC), 35 Amps (DC)
Common Mode Impedance150 kHz - 24 MHz: 15Ω ±20Ω 24 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
Voltage Division Factor9.5 dB +3 / -1 dB
Dimensions7 x 7 x 16 ¾ inches 17.7 x 17.7 x 42.5 cm
Weight7 lbs. / 3.1 kg
Compliant Test StandardsIEC -61000-4-6, CISPR 16-1-2
I/O rating for EUT/AE Ports250 VAC, 350 VDC
Max Input Voltage40 V
ApplicationTwo wire power cables
RF Input Connector50 Ω BNC (female)
I/O Connection5.2 mm banana socket with shrouded Sheath

Test Equipment Description

Com-Power CDN-M250E 150 kHz - 230 MHz Single line + Netural 50 Amp

The CDN-M250E series is used for testing products with two wire power supply lines. It can handle up to 50 Amps (AC) or 35 Amps DC power source. It has 5.2 mm shrouded banana socket for both EUT and AE power connection. The RF disturbance signal is injected using a BNC connector which can handle up to 40 V of input. The bottom surface of the CDN is not painted, so that it be properly grounded during the test.

All Com-Power CDNs can be purchased separately or part of the CIS series conducted immunity test system. The test system includes the ACS series power amplifier and accessories required to conduct the immunity testing. All Com-Power CDNs are individually calibrated.The Com-Power CDN-M250E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2.

Application

During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to each line. In addition, CDNs provide the required common mode impedance to the EUT, isolation to the auxiliary equipment via common mode decoupling of the disturbance signals and provide uninterrupted communication between the EUT and auxiliary equipment.

Before you begin testing with the CDN-M250E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150Ω to 50Ω adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value given in the table below. The ADA-515-2 and accessories needed for this test are available from Com-Power.

Test Levels
Open Circuit Voltage
Umr
10.167
30.5
101.67

Umr= Voltage level measured at the output of the 150Ω to 50Ω adapter (ADA-515-2)

Typical Data

Com-Power CDN-M450E Typical Data

Com-Power CDN-M450E Typical Data

Associated EMC Test Equipment

9 other products in the same category: