M Series

Quick Links

Information

Viewed products

Com-Power CDN-M450E 150 MHz to 230 MHz Coupling Decoupling Network View larger

Com-Power CDN-M450E 150 MHz to 230 MHz Single line Plus Netural 50 Amp

New

  • 150 kHz to 230 MHz Frequency Range
  • Current Handling 50 Amps AC
  • Individual calibration
  • Meets CISPR 16-1-2 and 61000-4-6 Requirements
  • Three Year Warranty

More details

In Stock

Request Quote/More Info

PDF Downloads

Specifications

Voltage Rating250 VAC / 350 VDC (Line to Ground)
Current Rating50 Amps AC / 35 Amps DC (Max
Common Mode Impedance150 kHz - 24 MHz: 150Ω ± 20Ω 24 MHz - 80 MHz: 150Ω + 60Ω / -45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / -60Ω
RF Input Voltage40 V (Max)
Decoupling of Common Mode Disturbance≥40dB (EUT/AE)
Voltage Division Factor9.5 dB +3 / -0.5
Dimensions7 x 7 x 16 ¾ inches or 17.7 x 17.7 x 42.5 cm
Weight8 lbs. or 3.6 kg
Compliant Test StandardsIEC / EN 61000-4-6, CISPR 16-1-2
ApplicationFour conductor power cable
RF Input Connector50 Ω BNC (Female)
AE and EUT Connections5.2 mm shrouded banana sockets

Test Equipment Description

Com-Power CDN-M450E is a part of the series of Coupling/Decoupling Networks designed specifically for testing product for conducted immunity per IEC/EN 61000-4-6. The CDN-M450E is designed for testing products that uses four conductor power cable. It has five 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M450E can handle up to 50 Amps AC and 35 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding. All Com-Power CDNs are individually calibrated. The Com-Power CDN-M450E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system.

This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test. Coupling Decoupling Network CDN-M450E. During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to the power supply lines. In addition, CDNs provide required common mode impedance between the power supply lines and ground, minimize interference to the auxillary equipment via common mode decoupling of the disturbing signals and provide uninterrupted path for the power to the EUT. Before you begin testing with the CDN-M450E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150Ω to 50Ω adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value.

The CDN-M450E is designed for testing products that uses four conductor power cable. It has five 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M450E can handle up to 50 Amps AC and 35 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding.

All Com-Power CDNs are individually calibrated. The Com-Power CDN-M450E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test. 

Application

During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to each line. In addition, CDNs provide the required common mode impedance to the EUT, isolation to the auxiliary equipment via common mode decoupling of the disturbance signals and provide uninterrupted communication between the EUT and auxiliary equipment.

Before you begin testing with the CDN-M450E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150Ω to 50Ω adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value given in the table below. The ADA-515-2 and accessories needed for this test are available from Com-Power.

Test Levels
Open Circuit Voltage
Umr
10.167
3.5
< 101.67


Typical Data

Com-Power CDN-M450E Typical Data

Com-Power CDN-M450E Typical Data

Associated EMC Test Equipment