Damped Oscillatory Wave

Quick Links

Information

Viewed products

EMC Partner MIG-OS-OM Slow Wave Oscillatory Wave Generator View larger

EMC Partner MIG-OS-OM Slow Wave Oscillatory Wave Generator

New

  • Generates 1MHz and 100 kHz up to 3 kV
  • Voltage Output for use with 3-Phase CDN
  • Output for Magnetic Field Testing
  • EN/IEC 61000-4-18 Testing
  • EN/IEC 61000-4-10 Testing w/ MF1000-1

More details

Request Quote/More Info

Test Equipment Description

EMC Partner MIG-OS-OM Application:

The MIG-OS-OM includes damped oscillatory tests 1MHz and 100 kHz up to 3 kV in accordance with EN/IEC 61000-4-18. This standard defines a dual output for differential mode tests. Additionally magnetic field test in accordance with EN/IEC 61000-4-10 can be carried out. The MIG-OS-OM generates: 100 kHz and 1 MHz defined in EN/IEC 61000-4-18 damped oscillatory waves. Accessory: CDN2000-06-25 for coupling into control and signal lines. 100 kHz and 1 MHz defined in EN/IEC 61000-4-10 damped oscillatory magnetic field tests. Accessory: MF1000-1 or MF1000-2 plus MF1STAND

Oscillatory Wave Generator according to IEC 61000-4-10 and IEC 61000-4-18 (slow wave). Requires MF1000-1 and and CDN2000-06-25 or CDN-1P-16 OSI.

Standards Met:

  • IEC 61000-4-18
  • IEC 61000-4-10 with (MF1000)

EMC Partner MIG-OS-OM Benefits:

  • Impulse repeatability pulse to pulse
  • Save operator time with the automated test routines and test report facility
  • Combined test system

EMC Partner DOW Test Systems Accessories:


CDN-1P-04-16 OSIManual single phase CDN with line voltages L to N=280V line current 16A. Coupling path selection, CM, L+N to PE for slow damped oscillatory waves 100kHz and 1MHz, 200 Ohm fast damped oscillatory waves only, 3, 10, 30MHz, 50 Ohm
CDN2000-06-25 480VManual three phase CDN with line voltages L to N=280V and L to L=480V, line current 25A per phase. Coupling path selection EFT(5kV), DOW 100kHz and 1MHz (4kV), Surge and Ring up to 6kV. d.c. see user manual ! L-L=max. 600V, L-GND=max. 300V
CDN3000A-06-32 480VThree phase CDN with line voltages L to N=280V and L to L=480V, line current 32A per phase. Automatic coupling path selection for EFT, Surge, RING and Damped Oscillatory, Common mode coupling only up to max. 30MHz.
CDN3000A-06-32 690VThree phase CDN with line voltages L to N=400V and L to L=690V, line current 32A per phase. Automatic coupling path selection for EFT, Surge, RING and Damped Oscillatory. Common mode coupling only up to max. 30MHz.