Viewed products
Slow Wave, Fast Wave, Impulse voltage...
New
Warning: Last items in stock!
Availability date:
Electronic measurement and control equipment in the energy distribution network can be susceptible to environmental disturbances. The latest development from EMC PARTNER AG is a high voltage test system for damped oscillatory wave testing.
DOW3000 is a configurable test system that can be extended for Slow Wave, Fast Wave, Impulse voltage test or any combination of all three. This provides optimum and cost efficient capabilities to a wide spectrum of users. This unique system includes an integrated 32A three phase coupler which enables both Slow and Fast DOW signals to be directly injected into the EUT. Additionally, DOW3000 is the first tester with integrated 0.5J impulse, required together with the DOW, for product standard testing.
A modern user interface provides an easy to follow menu structure. Graphic and contextual help functions make operation simple and efficient.
Slow & Fast Damped Oscillatory Wave Generator 100KHz to 30MHz According to IEC 61000-4-18, IEC 60255-22-1, ANSI C37.90.1 1.2/50us impulse up to 8kV. IEC 60060-1, IEC 61180-1 With MF1000 also IEC 61000-4-10. Built in automatic 3-Phase CDN
CDN-1P-04-16 OSI | Manual single phase CDN with line voltages L to N=280V line current 16A. Coupling path selection, CM, L+N to PE for slow damped oscillatory waves 100kHz and 1MHz, 200 Ohm fast damped oscillatory waves only, 3, 10, 30MHz, 50 Ohm |
CDN2000-06-25 480V | Manual three phase CDN with line voltages L to N=280V and L to L=480V, line current 25A per phase. Coupling path selection EFT(5kV), DOW 100kHz and 1MHz (4kV), Surge and Ring up to 6kV. d.c. see user manual ! L-L=max. 600V, L-GND=max. 300V |
CDN3000A-06-32 480V | Three phase CDN with line voltages L to N=280V and L to L=480V, line current 32A per phase. Automatic coupling path selection for EFT, Surge, RING and Damped Oscillatory, Common mode coupling only up to max. 30MHz. |
CDN3000A-06-32 690V | Three phase CDN with line voltages L to N=400V and L to L=690V, line current 32A per phase. Automatic coupling path selection for EFT, Surge, RING and Damped Oscillatory. Common mode coupling only up to max. 30MHz. |