Viewed products
AC Power (up to 20 kHz): 3380 watts...
10 kHz to 10 MHz Frequency Range...
New
Warning: Last items in stock!
Availability date:
The AE Techron 7548 amplifier is a 3300-VA, DC-enabled, high-powered unit designed to provide very low noise, low harmonic distortion and fast slew rates. It can safely drive a wide range of resistive, inductive loads. Typical use includes as a power source for EMC testing in applications that require both continuous AC or DC signals and significant short term (burst) signals. Two 7548 connected in series can output 240V RMS at 20A RMS.
The 7548 can be used singly or in series to meet or exceed Aviation AC power tests requirements found in RTCA/DO 160. The 7548 also can be used as a Voltage or Current Amplifier, so it also makes an ideal choice for driving large Helmholtz coils specified in MIL STD 461 or various Automotive Standards. In addition, the 7548 can be connected to form large, low-distortion, two- or three-phase power systems with voltages of up to 600V L-L and 360 L-N, ideal for MILSTD-704F (AC and 28V DC tests).
Testing performed at 208V/415V AC. 7548 amplifiers can operate from 400V AC ±10%. Since these amplifiers have an unregulated power supply, low line conditions may slightly affect the maximum voltage potential. All testing was performed in Controlled-Voltage (CV) mode. Accuracy was measured when driven into a 10-ohm load with between 0.1V DC and 6V DC or between 0.2V AC and 5V AC presented at its inputs.
Frequency Response, DC—30 kHz (1 watt): +0.1 to -0.5 dB
8-Ohm Power Response (continuous duty)
Maximum Continuous Output Power: 3300 watts RMS
Slew Rate: >35 V/µSec
Residual Noise, 10 Hz to 20 kHz: <250 µV (<0.25 mV)
Unit to Unit Phase Error: ±0.1 degrees at 60 Hz
Phase Response (10 Hz - 10 kHz): ±5 degrees plus 600 nsec propagation delay
THD (DC - 20 kHz): <0.25%
Output Offset: <±200 µV
Output Offset Current: <10 mA, DC
DC Drift,
From Cold to Maximum Operating Temperature: <±400 µV
After 20 Minutes of Operation: ±200 µV
Output Impedance: 3.2 mΩ in Series with 2.2 µH
Input Characteristics;
Balanced with ground: Three-terminal barrier-block
connector, 20 kΩ differential
Unbalanced: BNC connector, 10 kΩ single-ended
Gain:
Voltage Mode: 20 volts/volt
Current Mode: 20 amperes/volt
Gain Linearity (over input signal, from 0.2V to 5V):
DC: 0.0125%
AC: 0.030%
Max Input Voltage: ±10V, balanced or unbalanced
Input Impedance: 20 kΩ differential
Common Mode Rejection Range: ±11V DC maximum
Common Mode Rejection Ratio: Better than -65 dB
Front Panel LED Displays indicate: Ready, Standby, Fault
Soft Touch Switches for: Run, Stop, Reset
LCD Display: Can be configured for up to four simultaneous displays reporting one, two, or all four of the following: Vp, VRMS, Ap, ARMS. Also reports any fault conditions that occur and suggests corrective action.
Back Panel Power Connection: NEMA-style locking receptacle; matching AC connector also included
Signal Output: 4-position terminal barrier block (OUTPUT / COMMON / SAMPLED COMMON / CHASSIS GROUND); resistor installed between SAMPLED COMMON AND CHASSIS GROUND is a 2.7-ohm, 2W, 5%, metal-oxide resistor
Signal Input: User-selectable BNC or Barrier Strip, Balanced or Unbalanced
Interlock Connector: 25-pin D-sub connector used for amplifier control and status applications; also used in multi-amplifier applications
Current Monitor: 20A/V ±1%; 10A/V ±1% (differential configuration)
Reporting: System Fault, Over Temp, Over Voltage, Over Load
Remote Control via Interlock Connector: Force to Standby, Reset after a Fault
Over/Under Voltage: ±10% from specified supply voltage amplifier is forced to Standby
Over Current: Breaker protection on both main power and low-voltage supplies
Over Temperature: Separate output transistor, heat sink, and transformer temperature monitoring and protection
Chassis:The amplifier is designed for stand- alone or rack- mounted operation. The chassis is aluminum with a black powder-coat finish. The unit occupies five EIA 19-inch-wide units.
Weight: 103 lbs (46.7 kg), Shipping 115 lbs (52.2 kg)
AC Power: Three-phase, 208V AC (±10%), 47-60 Hz, 20A AC service; (400V AC (±10%), 15A model available)
Operating Temperature: 10°C to 50°C (50°F to 122°F), maximum output power de-rated above 30°C (86°F).)
Humidity: 70% or less, non-condensing
Cooling: Forced air cooling from front to back through removable filters via four 100ft3/min. fans. No space is required between rack-mounted amplifiers. Air filters are removeable from the rear via one fastener per side and may be eliminated if cabinet filtration is provided.
Dimensions: 19” x 22.8” x 8.75” (48.3 cm x 57.9 cm x 22.2 cm)