S Type for USB and HDMI

Quick Links

Information

Viewed products

Com-Power CDN-USB-AE Coupling Network for USB Cable w/ Type A Connector - EMC Test Equipment View larger

Com-Power CDN-USB-AE USB CDNs with Type A Connector

New

  • 150 kHz - 230 MHz Fequency Range
  • CDN for USB cable with type A connector
  • Connections: EUT: Type A, AE: Type B
  • Designed for EN/IEC 61000-4-6
  • Calibration & 3-Year Warranty

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Specifications

Voltage Rating30 V AC / 30 V DC (Line to Ground)
Frequency Range150 kHz to 230 MHz
Standards MetIEC / EN 61000-4-6
RF Connector50 Ω BNC (Female)
Mains & EUT ConnectionsEUT: Type A, AE: Type B
Common Mode Impedance150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
Current Rating1 Amp (Max)
Application/Test TypeUSB cable with type A connector
RF Input Voltage40 V (Max)
Voltage Division Factor9.5 dB +2 / -1
Decoupling of Common Mode Disturbance≥ 50dB (EUT/AE)
Dimensions8.5 x 4.5 x 3.5 inches 21.5 x 11.4 x 8.8 cm
Weight2 lbs. 0.9 kg

Test Equipment Description

The Com-Power CDN-USB-AE is designed for testing products that uses USB cables for communication. It has a USB type A on the EUT side and USB Type B on the AE side. The CDN-USB-AE can handle up to 1 Amp of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF Input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding.

All Com-Power CDNs are individually calibrated. The Com-Power CDN-USB-AE fully complies with the requirements contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test.

Application

During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to each line. In addition, CDNs provide the required common mode impedance to the EUT, isolation to the auxiliary equipment via common mode decoupling of the disturbance signals and provide uninterrupted communication between the EUT and auxiliary equipment.

Before you begin testing with the CDN-USB-AE you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150Ω to 50Ω adapter (ADA-515-2) connected to the EUT port of the CDN is approximately equal to the Umr value given in the table below. The ADA-515-2 and accessories needed for this test are available from Com-Power.

Test Levels
Open Circuit Voltage
Umr
10.167
30.5
101.67

Umr= Voltage level measured at the output of the 150Ω to 50Ω adapter (ADA-515-2)

Typical Data

CDN-USB-AE Accessory Kit:

Associated EMC Test Equipment

10 other products in the same category: