Teseq RF Immunity Generators

Quick Links

Information

Viewed products

Sale! Teseq NSG 4070C-35 Test System for Conducted & Radiated Immunity, 4 kHz to 1 GHz Signal Generator, 35 Watt Amplifier View larger

Teseq NSG 4070C-35 Test System for Conducted RF Immunity to IEC 61000-4-6

Refurbished

  • In stock, calibrated and ready to ship
  • Turnkey CDN, BCI and EM Clamp solutions for IEC 61000-4-6
  • 35 Watt, 150kHz to 230 MHz Integrated class A power amplifier (See Teseq NSG4070-45 for expanded capabilities)
    Multiple EUT monitoring options
  • 5.7“ TFT color display
  • Internal, menu-based control software
  • Basic remote control software and report generator included
  • Whisper mode

More details

In Stock

$19,500.00 + Shipping

Request Quote/More Info

PDF Downloads

Test Equipment Description

The Teseq NSG 4070C-35 Compact immunity test system NSG 4070C, 4 kHz - 1 GHz RF generator and power meter (with integrated power amplifier 35 W module 150 kHz - 230 MHz) is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to EN/IEC 61000-4-6, Namur and several automotive BCI standards. Anyone who spends a considerable amount of time on test level setting, connecting EUT monitoring or writing test reports can now carry out immunity testing in a much more efficient manner with the 4th generation of NSG 4070. Its modular set-up using internal or external amplifiers enables a large variety of applications. The powerful and easy to use firmware makes the NSG 4070 independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front panel.

Teseq NSG 4070 - How to Setup Remote Control to PC

The optical link adapter can be very difficult to connect and should be avoided unless absolutely needed. Utilizing a LAN cable, connecting to the Teseq NSG 4070 software for remote use is simple and completed in a few simple steps. The EMC Shop stocks the Teseq NSG 4070 and all the accessories to complete RF conducted immunity testing to IEC 61000-4-6, ISO 11452-4MIL-STD 461 CS114 and other test standards.

Teseq NSG 4070 Test Generator Back PanelTeseq NSG 4070C-35 Test System for Conducted & Radiated Immunity, 4 kHz to 1 GHz Signal Generator, 35 Watt Amplifier

Teseq NSG 4070C Specifications

White Noise Generator
Frequency Range150 kHz to 230 MHz
RF Level
Level rangemin -60 dBm/Hz to -40 dBm/Hz
Broadband signal flatness< ±3 dB (150 kHz to 80 MHz)
Out of band attenuation> 20 dB (100 MHz)
Pulse Modulation
Rise/fall time (10%/90%)< 1 µs
Modulation frequency range1 Hz to 10 Hz
Frequency resolution1 Hz
Duty cycle10% to 90%
Power Meter
Frequency range9 kHz to 1 GHz
Linear Measurement Range
Channel 1-35 dBm to +27 dBm
Channel 2, 3-45 dBm to +20 dBm
Max. input/no damage
Channel 1-3+28 dBm
Noise Level>5 dB below the measurement range
Input Return Loss>20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
ConnectorBNC socket, 50 Ω
Accuracy 10 to 30°C
Power Amplifier
Frequency Range150 kHz to 230 MHz
Input Impedance50 Ω
Output Impedance50 Ω
Input Return Lossmin. 10 dB
Output Return LossNominal min. 9.5 dB, 0 dB without damage
Gainmin.: 50 dB
Gain Flatnessmax. +/- 3 dB
Saturated OutputPowermin. 49 dBm
Linear Output Powermin. 48 dBm
Max. input power without damagemax. +10 dBm
Harmonic distortion at linear output powertyp. < -20 dBc
Analog Ports
Front Panel
Generator OutputN socket 50 Ω, 4 kHz to 1 GHz
Power Amplifier InputN socket 50 Ω, max. +10 dBm
Power Amplifier OutputN socket 50 Ω
Power Meter Channel 1 to 3as defined in chapter “Power meter“
Back Panel
Monitoring Input AnalogBNC socket, 0 to 24 V Ri=15 kΩ, 6 mV resolution
External modulation inputBNC socket, impedance >10 kΩ, level: 1 Vpp to get 100% AM, 1 Hz to 50 kHz
Digital Ports
Front Panel
USBUSB host connector for USB stick, keyboard, mouse
Back Panel
User portD-Sub 15 pole with
4 TTL inputs,
4 TTL outputs,
+12 V / 800 mA, -12 V/200 mA and +5 V/800 mA power supply
Monitoring digital inputBNC socket
0 to 24 V via optical coupler Ri=1.5 kΩ,
switching threshold approx. 2 to 3 V
Monitoring optical inputLWL (Light wave connector), HP versatile link HFBR0501 series 40 kBd, (avoid scattered light on the back panel)
Trigger inputBNC socket, TTL for external triggering, max. frequency 100 Hz, trigger delay <10 ms
RS232D-Sub 9 pole, up to 115200 Bd
RS232 opticalConnector 2 x HFBRx523 socket for 1 mm fiber optic cable with length between 5 m and 30 m with 115200 Bd, for other distances 38400 Bd, max. 50 m
2x USBUSB host connector for USB stick, keyboard, mouse
USB device connectorFor remote control
NetworkRJ45, Ethernet 10/100 BASE-T
General Specifications
Mains Input100 to 240 VAC, 50/60 Hz, autoranging
Power Consumptionapprox. 415 W
Operating Temperature range0°C to 40°C
Storage Temperature range-20°C to 60°C
Relative Humidity95% / 30°C (no moisture condensation)
EMCDIN/EN 61326-1:2006
ShockDIN/EN 60068-2-27
VibrationDIN/EN 60068-2-6
Protection ClassDIN/EN 61010-1/IEC 61010-1
Size (W x H x D)45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
Weightapprox. 15 kg (with internal power amplifier),
approx. 8 kg (without internal power amplifier)
Size of Cardboard Box80 cm x 61 cm x 34 cm
(also for options ATN 60xx and/or LE 4070 additional space available)
Weight of Cardboard BoxApprox. 8 kg (empty)

Associated EMC Test Equipment