Teseq EFT/Burst Generators

Quick Links

Information

Viewed products

Teseq NSG 3060A Modulator Solution For 6 kV Applications View larger

Teseq NSG 3060A Modulator Solution For 6 kV Applications

New

  • One box solution system
  • Surge voltage up to 6.6 kV allows overtesting
  • Easy to use 7” color touch screen
  • IEC and ANSI coupling methods
  • Parameters can be changed while test is running
  • Wide range of optional test accesories
  • High accuracy switching
  • technology meets ANSI coupling requirements

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The Teseq’s new NSG 3060A conducted immunity generator takes the proven, user-friendly design of the highly successful NSG 3000 series to a new level. This innovative design uses modular architecture to provide a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.

Designed to fulfill requirements for CE mark and ANSI C62.41 testing, the Teseq NSG 3060A performs tests for Combination wave surge, Ring wave and Electrical Fast Transient (EFT) pulses as well as Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.

Using state of the art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements. With its powerful processors, the NSG 3060A can completely fulfill the unique coupling requirements specified by ANSI C62.41. This standard requires that the pulse amplitude be adjusted for the phase position of the pulse on the AC mains, and for the amplitude of the mains voltage.

A 7” touch panel display with superb contrast and color is the most striking feature of the new NSG 3060A. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment.

The user-friendly graphic display speeds test setup. Each parameter’s value is highly visible, and all settings can be quickly selected and modified with the generously sized touch input buttons. A stylus is not necessary, and ramp functions are programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values changed easily.

The users can make manual parameter changes using the thumbwheel while a test is under way, providing an effective and fast method for identifying critical threshold values. The Test Assistance (TA) function allows users to initiate standardized test with just a few “clicks” to achieve quick, reliable results in a development environment.

The Teseq NSG 3060A has an Ethernet port for external PC control. The Windows-based control software simplifyes test programming and allows compilation of complex test sequences with diverse pulse types. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.

ModelEFT/BurstSurgePQTRing waveTelecomSurge
NSG 3060A-IEC     
NSG 3060A-ANSI     
NSG 3060A-FULL     

The Teseq NSG 3060A performs tests according to the following Specifications
Combination wave pulse 1, 2/50 - 8/20 µs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41
Parameter Value
Pulse voltage (open circuit)±200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit)±100 A to 3.3 kA
Impedance2/12 Ω
Polaritypositive / negative / alternate
Pulse repetition10 s* up to 9’999 s (in 1 s steps)
Test duration1 to 99’999 pulses, continuous
Phase synchronizationasynchronous, synchronous 0 to 359º (in 1º steps)
CouplingANSI / IEC / external
* Repetition rate depends on voltage200 to 4400 V = 10 s repetition time
4401 to 6600 V = 20 s repetition time
Ring wave 0.5 µs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Parameter Value
Pulse voltage (open circuit)± 200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit)±16.6 to ±550 A, ±10%
±6.6 to ±220 A, ±10%
±1 to ±33 A, ±10%
Impedance12/30 Ω
Polaritypositive / negative / alternate
Pulse repetition10 s* up to 9’999 s (in 1 s steps)
Test duration1 to 99’999 pulses, continuous
Phase synchronizationasynchronous, synchronous 0 to 359º (in 1º steps)
CouplingANSI / IEC / external
* Repetition rate depends on voltage200 to 4400 V = 10 s repetition time 4401 to 6600 V = 20 s repetition time
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Parameter Value
Pulse amplitude±200 V to 4.8 kV (in 1 V steps) - open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency100 Hz to 1000 kHz
Polaritypositive / negative / alternate
Repetition time10 ms to 9'999 ms
Burst time0.01 ms to 9'999 ms, single pulse
Test duration1 s to 9’999s, 1 min to 1600 min, endless
Phase synchonizationasynchronous, synchronous 0 to 359º (in 1º steps)
Couplinginternal / external
Dips & Interrupts
conforms to IEC / EN 61000-4-11, IEC / EN 61000-4-29
Parameter Value
Dips & InterruptsFrom EUT voltage input to 0 V, 0% (1)
Uvar with optional variacdepending on model (VAR 3005A)
Uvar with step transformer0, 40, 70, 80% (INA 650xA)
Peak inrush current capability> 500 A (at 230 V)
Switching times1 to 5 μs (100 Ω load)
Event time (T-Event)20 µs to 9999 s, 0.5 to 9’999 cycles
Repetition time10 ms to 9’999 ms, 1 to 9’999 s
Test duration1 to 99’999 events, endless
Phase synchronizationasynchronous, synchronous 0 to 359º (in 1º steps)
(1) In combination with VAR 3005A-S16, effective minimal dip voltage ~8 V. As specified in IEC 61000-4-11, chapter. 5.1 a test voltage level from 0% to 20% of the rated voltage is considered as a total interruption.
Variation test (with VAR 3005A-S16 only)
Parameter Value
Uvar with optional variacup to 265 V (in 1 V steps) or up to 115% Uin (in 1% steps)
Decreasing time Td1 ms to 9.999 ms, 0.5 to 9999 cycles, abrupt
Time at reduced voltage Ts1 ms to 9.999 ms, 0.5 to 9999 cycles,
Increasing time Ti1 ms to 9.999 ms, 0.5 to 9999 cycles,
Repetition time1 s to 9’999 s
Events1 to 99’999
Pulsed magnetic field in conjunction with MFC 30
conforms to IEC/EN 61000-4-9
Parameter Value
Field100 to 1200 A/m
Polaritypositive / negative / alternate
Repetition time10 s to 9999s (in 1 s steps)
Impedance2 Ω
Coil / impedance factor0.01 to 100.00
Test duration1 to 9’999 pulses, endless
Phase synchronizationasynchronous, synchronous 0 to 359º (in 1º steps)
Power magnetic field in conjunction with MFT 30 or MFO 6501A and MFC 30 / MFC 300
conform to IEC/EN 61000-4-8
Parameter Value
Field1 to max. 40 A/m (in 1 A/m steps)
Frequency50/60 Hz
Coil factor0.01 to 99.99
Test duration1 to 9’999 pulses, continuous
Internal Coupling Network
Parameter Value
EUT supply1-phase
EUT VACUp to 300 Vrms *, 50 / 60 Hz (phase - neutral)
EUT VDCUp to 300 VDC
EUT current1 x 16 Arms continuous (over heat protected)
Connections
Front panel- EUT: 4mm banana plug
- Burst OUT 50 Ω SHV
- Trigger out BNC
Rear panel- EUT supply: banana plug 4 mm
- Additional ground connector
- Instrument supply 85 V to 264 VAC
- Connector surge HV – COM
SurgeStandard coupling as per IEC 61000-4-5
Coupling modeLine to Line
Line(s) to ground
Mains decoupling1.5 mH 0% + 35%
Decoupling attenuationResidual pulse voltage on EUT power supply inputs 15 % max.
Residual voltage on non-pulsed EUT power supply inputs 15 % max
EFT (Burst)Standard coupling all lines to ref ground (GND) IEC / EN 61000-4-4
L, N, PEto ref GND
Any lines and combinationto ref GND
Lto ref GND
Nto ref GND
PEto ref GND
L, Nto ref GND
L, PEto ref GND
N, PEto ref GND
PQTDips & interrupts to phase L
Technical Specification
Instrument supply85 to 265 VAC, 50 / 60 Hz
Dimensions NSG 3060A-IEC19”; 6 HU, 448 x 289 x 500 mm (W x H x D)
Weight NSG 3060A30 kg (66 lbs)
Options
CDN 3063A-C32Three phase 480 V / 32 A automatic coupling decoupling networks for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3063A-C63Three phase 480 V / 63 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3063A-C100Three phase 480 V / 100 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3425Burst EFT capacitive coupling clamp for data line coupling per IEC 61000-4-4
CDN 117A-C6-4-1Coupling networks for unsymmetrical signal-/data lines (surge)
CDN 118A-C6-4-1Coupling networks for symmetrical signal-/data lines (surge)
CDN HSS-2Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000 4-5 on unshielded symmetrical high speed telecom lines (Ethernet)
PVF BKIT1 Burst/EFT verification set
MD 210Voltage differential probe 7 kV common / differential 1000:1 / 100:1
MD 300Current probe 5 kA
Accessories for IEC/EN 61000-4-11
TVT 1-250-16Manual step transformer, 16 AAC, 0/40/70/80%
VAR 3005A-S16Automatic single variable transformer, 1 x 16 A
Accessories for IEC/EN 61000-4-8/-4-9
MFO 6501AManual magnetic field option -4-8
MFC 30Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8;
Surge* max. 1200 A/m -4-9
MFC 300Magnetic field coil 1 x 1 m; max. 330 A/m -4-8