Rent Teseq (Schaffner) CDN 163 3-Phase, 100 Amp EFT/Burst Coupling Network

Used

  • Monthly Rental - Ships Immediately
  • Ideal for 3 Phase DUT IEC 61000-4-4 testing
  • For AC and DC up to 100 Amps per channel
  • EUT Supply voltage to 690 VAC and 1000 VDC
  • Parallel channels for Single Phase/DC application and increase current capability
  • Compatible with all burst/EFT generators up to 8 kV
  • Built-in temperature monitor

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Test Equipment Description

High frequency pulse signals can result in cross-talk between conductors running in parallel even over short distances. This behavior is taken into account in the latest and currently valid edition of the EFT/ burst standard IEC/EN 61000-4-4 (2004). Only the single coupling mode of „all conductors together against reference ground“ is called for in interference immunity measurements with fast transients.

This simplifies the construction and utilization of coupling networks considerably, complicated coupling switches can be omitted.

The CDN 163 is a 3-phase EFT/burst pulse coupling network for large EUT currents. Although designed for continuous duty at up to 100 A per phase, the unit can be subjected to considerably higher currents for short durations. For 1-phase or DC applications it‘s possible to connect the input channels parallel, thus to increase the EUT current. As a result, high inrush currents or pulse-shaped peak currents can be handled with ease. The current limitation is largely down to a matter of thermal loading. A built-in thermometer enables the heating effect to be monitored. The type of construction, using a metal housing for use directly on the ground reference plane, ensures excellent HF earthing. The power and EUT connections take the form of generously dimensioned screw terminals.

Technical Specifications
EUT (supply) Voltage690 VAC, line-to-line and line-to-ground
1000 VDC, line-to-line and line-to-ground
EUT Current (AC or DC)≥100 A continuous
150 A for approx. 30 min
EFT/Burst Pulse Peak VoltageUp to 8000 V
Leakage current to ground7.1 mA max. (short duration – during power up)
TerminalsScrew terminals, 50 mm² rated for 150 A
Temperature MonitoringBimetal-thermometer -0 to +120°C
Grounding4 mm combined banana and screw terminal (safety grounding). Via housing bottom plate and brackets (FH ground to test setup ground plate).
Dimensions L x W x H380 x 150 x150 mm (15 x 5.9 x 5.9“)
Weight4.2 kg (9.3 lbs) approx.
EFT/Burst Coupling Network OptionsINA 163: safety banana plug set 6 to 4 mm (10 pcs)
INA 164: Measuring adapter incl. 5 pcs safety banana plugs
CAS 3025: Burst calibration set

Associated EMC Test Equipment